DAEnetIP3
User Manual
-
25
-
In “Low” mode the output level is inverted when the rising analog input
level crosses the LT+LH/2 limit and when the falling analog input level
crosses the LT-LH/2 limit.
In “High” mode the output level is inverted when the rising analog input
level crosses the HT+HH/2 limit and when falling analog input level
crosses the HT-HH/2 limit.
In “Acc” mode the output level is inverted when the rising analog input
level crosses the HT+HH/2 and when the rising analog input level
crosses the LT-LH/2.
In
“Low/High” mode the output level is inverted when the rising (falling)
analog input level crosses the LT+LH/2 (HT-HH/2) and when the rising
(falling) analog input level crosses the HT+HH/2 (LT-LH/2).
7.5.9.
Inverting and schedule
In this mode (Figure 20) the digital output states are inverted by the two time
events (Time 1 and Time 2). The user can not control manually the outputs in this
mode.
Figure 20
. Inverting and schedule
7.5.10.
Inverting and remote
In this mode the output can be inverted by input (digital or analog) from another
DAEnetIP3 controller over the network. The user can not control manually the
outputs in this mode.