Baud rat
e
The baud rate states the number of characters transferred per second via
the interface. Selection depends on the properties of the connected
devices and the cable length between the devices: For longer lines, a lower
baud rate should be selected to achieve error-free communication.
The following rates can serve as a guide:
l
from 15 m: 1000 kbaud (standard setting)
l
up to 30 m: 500 kBaud
l
up to 45 m: 333.3 kbaud
l
up to 60 m: 250 kBaud
l
up to 150m: 100 kbaud