Configuring LAN/WLAN/WWAN interfaces
l
l
l
USB interfaces
l
l
(interface for USB memory)
4.12.1
SDI 12
The
SDI 12
interface is configured at the sensor terminals 33 and 34
(
"Configuring digital inputs" on page 105
).
There are two approaches to operate a sensor via
SDI 12
:
l
Manual creation (sensor address is required)
l
Automatic sensor detection
Manual creation via sensor address
Proceed as follows to create a connected
SDI 12
sensor manually:
l
At the
SDI 12
interface, create the channel for the
SDI 12
master (
SDI 12
master)
l
At the
SDI 12
master, create the channel for the
SDI 12
sensor (
SDI 12
sensor)
l
At the
SDI 12
sensor, create the data channels (
SDI 12
data)
Automatic sensor detection
You can also start an automatic search to detect the sensors connected via
SDI 12
automatically:
At the
SDI 12
interface, create the channel for the
SDI 12
master and
start the automatic search:
SDI 12
master
To perform a
SDI 12
measurement, you must first connect at least one
SDI 12
measurement sensor to the sensor terminal 33 (D IN /
SDI 12
).
4.12.1.1
SDI 12 Master
Create a channel for the SDI-12 Master from the context menu
Create
Channel
→
SDI-12 Master
of the
SDI 12
interface.