About Your System
49
Sector not found
Seek error
Seek operation
failed
Faulty hard drive, USB
device, or USB medium.
Replace the USB medium or
device. Ensure that the USB
or SAS backplane cables are
properly connected. See
"Troubleshooting a USB
Device" on page 160 or
"Troubleshooting a Hard
Drive" on page 174 for the
appropriate drive(s) installed
in your system.
Shutdown failure
General system error.
See "Getting Help" on
page 193.
Sparing mode
disabled. For
sparing mode,
matched sets of
three must be
populated across
slots.
The memory configuration
does not match the setting in
BIOS. The BIOS setting has
been disabled.
Reconfigure the memory
modules for Memory
Sparing mode. See "System
Memory" on page 98.
The amount of
system memory has
changed
Memory has been added or
removed or a memory
module may be faulty.
If memory has been added or
removed, this message is
informative and can be
ignored. If memory has not
been added or removed,
check the SEL to determine
if single-bit or multi-bit
errors were detected and
replace the faulty memory
module.
See "Troubleshooting
System Memory" on
page 167.
Table 1-2.
System Messages
(continued)
Message
Causes
Corrective Actions
book.book Page 49 Monday, June 15, 2009 11:33 AM
Summary of Contents for PowerEdge T710
Page 1: ...Dell PowerEdge T710 Systems Hardware Owner s Manual ...
Page 78: ...78 Using the System Setup Program and UEFI Boot Manager ...
Page 194: ...194 Getting Help ...
Page 204: ...204 Glossary ...
Page 210: ...Index 210 ...
Page 211: ...Index 211 ...
Page 212: ...212 Index ...
Page 213: ...Index 213 ...
Page 214: ...214 Index ...