![Dell PowerEdge T710 Hardware Owner'S Manual Download Page 29](http://html.mh-extra.com/html/dell/poweredge-t710/poweredge-t710_hardware-owners-manual_79696029.webp)
About Your System
29
E1420
CPU Bus parity
error. Power
cycle AC.
The system BIOS has
reported a processor bus
parity error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 193.
E1422
CPU # machine
check error.
Power cycle
AC.
The system BIOS has
reported a machine check
error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 193.
E1610
Power Supply #
(### W)
missing. Check
power supply.
Specified power supply
was removed or is missing
from the system.
See "Troubleshooting
Power Supplies" on
page 165.
E1614
Power Supply #
(### W) error.
Check power
supply.
Specified power supply
has failed.
See "Troubleshooting
Power Supplies" on
page 165.
E1618
Predictive
failure on
Power Supply #
(### W). Check
PSU.
An over-temperature
condition or power supply
communication error has
caused the predictive
warning of an impending
power supply failure.
See "Troubleshooting
Power Supplies" on
page 165.
E161C
Power Supply #
(### W) lost
AC power.
Check PSU
cables.
Specified power supply is
attached to the system,
but it has lost its AC
input.
Check the AC power
source for the specified
power supply. If the
problem persists, see
"Troubleshooting Power
Supplies" on page 165.
Table 1-1.
LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions
book.book Page 29 Monday, June 15, 2009 11:33 AM
Summary of Contents for PowerEdge T710
Page 1: ...Dell PowerEdge T710 Systems Hardware Owner s Manual ...
Page 78: ...78 Using the System Setup Program and UEFI Boot Manager ...
Page 194: ...194 Getting Help ...
Page 204: ...204 Glossary ...
Page 210: ...Index 210 ...
Page 211: ...Index 211 ...
Page 212: ...212 Index ...
Page 213: ...Index 213 ...
Page 214: ...214 Index ...