About Your System
27
E1420
CPU Bus
parity error.
Power cycle
AC.
The system BIOS has
reported a processor bus
parity error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help."
E1422
CPU # machine
check error.
Power cycle
AC.
The system BIOS has
reported a machine check
error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help."
E1610
Power Supply
# (### W)
missing.
Check power
supply.
Specified power supply was
removed or is missing from
the system.
See "Troubleshooting
Power Supplies."
E1614
Power Supply
# (### W)
error. Check
power supply.
Specified power supply has
failed.
See "Troubleshooting
Power Supplies
E1618
Predictive
failure on
Power Supply
# (### W).
Check PSU.
A power supply fan failure,
an over-temperature
condition, or power supply
communication error has
caused the predictive
warning of an impending
power supply failure.
See "Troubleshooting
Power Supplies."
E161C
Power Supply
# (### W)
lost AC
power. Check
PSU cables.
Specified power supply is
attached to the system, but
it has lost its AC input.
Check the AC power
source for the specified
power supply. If the
problem persists, see
"Troubleshooting Power
Supplies."
Table 1-1.
LCD Status Messages
(continued)
Code
Text
Cause
Corrective Actions
Summary of Contents for POWEREDGE R710