Jumpers and Connectors
185
Jumpers and Connectors
System Board Jumper
For information on resetting the password jumper to disable a password, see
"Disabling a Forgotten Password" on page 193.
Table 6-1.
System Board Jumper Settings
Jumper
Setting
Description
PWRD_EN
(default)
The password feature is enabled
(pins 2-4)
The password feature is disabled, and iDRAC6
local access is unlocked at the next AC power
cycle
(pins 4-6)
NVRAM_CLR
(default)
The configuration settings are retained at system
boot (pins 3-5)
The configuration settings are cleared at the next
system boot (pins 1-3)