About Your System
25
E122C
CPU Power
Fault. Power
cycle AC.
A power fault detected when
powering up the
processor(s).
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 195.
E122D
Memory
Regulator #
Failed.
Reseat DIMMs.
One of the memory
regulators failed.
Reseat the memory
modules. See
"Troubleshooting System
Memory" on page 169.
If the problem persists,
see "Getting Help" on
page 195.
E122E
On-board
regulator
failed. Call
support.
One of the on-board voltage
regulators failed.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 195.
E1243
CPU # VCORE
Regulator
failure.
Contact
Support
Processor voltage regulator
failed.
Reseat the processor. See
"Troubleshooting the
Processors" on page 178.
If the problem persists,
see "Getting Help" on
page 195.
E1245
CPU # VIO
Regulator
failure.
Contact
support
Processor voltage regulator
failed.
Reseat the processor.
"Troubleshooting the
Processors" on page 178.
If the problem persists,
see "Getting Help" on
page 195.
E1310
Fan ## RPM
exceeding
range. Check
fan.
RPM of specified fan is
outside the intended
operating range.
See "Troubleshooting
System Cooling
Problems" on page 167.
Code
Text
Causes
Corrective Actions
book.book Page 25 Thursday, February 18, 2010 2:06 PM
Summary of Contents for 810
Page 1: ...Dell PowerEdge R810 Hardware Owner s Manual Regulatory Model E05S Regulatory Type E05S001 ...
Page 80: ...80 Using the System Setup Program and UEFI Boot Manager ...
Page 160: ...160 Installing System Components ...
Page 194: ...194 Jumpers and Connectors ...
Page 196: ...196 Getting Help ...
Page 202: ...Index 202 ...