Appendix E: UTP Cabling
xxx
|
xxx
124
installations utilizing UTP cable specifications. The SCS system supports either
of these wiring standards. The following table describes the standards for each
pin.
Pin
EIA/TIA 568A
EIA/TIA 568B
1
white/green
white/orange
2
green
orange
3
white/orange
white/green
4
blue
blue
5
white/blue
white/blue
6
orange
green
7
white/brown
white/brown
8
brown
brown
Table E.1: UTP wiring standards
Cabling Installation, Maintenance, and Safety
Tips
The following is a list of important safety considerations that should be
reviewed prior to installing or maintaining your cables:
•
Keep all UTP runs to a maximum of 30 meters each.
•
Maintain the twists of the pairs all the way to the point of termination, or
no more than one-half inch untwisted. Do not skin off more than one inch
of the jacket while terminating.
•
If bending the cable is necessary, make it gradual with no bend sharper than
a one inch radius. Allowing the cable to be sharply bent or kinked can
permanently damage the cable’s interior.
Summary of Contents for 1081AD
Page 1: ...Dell Server Console Switch User s Guide ...
Page 18: ...10xxx Product Overviewxxx ...
Page 32: ...24xxx Installationxxx Figure 2 8 Basic SCS Configuration ...
Page 38: ...30xxx Installationxxx Figure 2 10 Tiering the SCS With a UTP Analog Switch ...
Page 40: ...32xxx Installationxxx Figure 2 11 Tiering Legacy Switches ...
Page 46: ...38xxx Installationxxx ...
Page 88: ...80xxx OBWI Operationxxx ...
Page 112: ...104xxx Video Viewerxxx ...
Page 116: ...108xxx Terminal Operationxxx ...
Page 122: ...Appendix B Setup Port Pinoutsxxx xxx114 ...
Page 134: ...Appendix E UTP Cablingxxx xxx126 ...