![DeDietrich C 340 280 Installation And User Manual Download Page 93](http://html1.mh-extra.com/html/dedietrich/c-340-280/c-340-280_installation-and-user-manual_2462417093.webp)
Code
Display text Description
Adjustment range
Subme
nu
280
350
430
500
570
650
CP060
RoomT.
Holiday
Wished room zone tem
perature on holiday period
5 - 20 °C
Direct
zone
6
6
6
6
6
6
CP070
MaxRedu
ce
dRoomT.Li
m
Max Room Temperature
limit of the circuit in re
duced mode, that allows
switching to comfort mode
5 - 30 °C
Direct
zone
16
16
16
16
16
16
CP210
Zone HCZP
Comfort
Comfort footpoint of the
temperature of heat curve
of the circuit
15 - 90 °C
Direct
zone
15
15
15
15
15
15
CP220
Zone HCZP
Reduced
Reduced footpoint of the
temperature of heat curve
of the circuit
15 - 90 °C
Direct
zone
15
15
15
15
15
15
CP230
Zone Heat
ing Curve
Heating curve temperature
gradient of the zone
0 - 4
Direct
zone
1,5
1,5
1,5
1,5
1,5
1,5
CP240
ZoneRoo
mUnitInfl
Adjustment of the influ
ence of the zone room unit
0 - 10
Direct
zone
3
3
3
3
3
3
CP250
CalSon
deAmbZone
Calibration of Zone Room
Unit
-5 - 5 °C
Direct
zone
0
0
0
0
0
0
CP340
TypeRedu
cedNight
Mode
Type of reduced night
mode, stop or maintain
heating of circuit
0 = Stop heat de
mand
1 = Continue heat
demand
Direct
zone
0
0
0
0
0
0
CP470
Zone screed
drying
Setting of the screed dry
ing program of the zone
0 - 30 Days
Direct
zone
0
0
0
0
0
0
CP480
ScreedStart
Temp
Setting of the start temper
ature of the screed drying
program of the zone
20 - 50 °C
Direct
zone
20
20
20
20
20
20
CP490
ScreedStop
Temp
Setting of the stop temper
ature of the screed drying
program of the zone
20 - 50 °C
Direct
zone
20
20
20
20
20
20
CP640
OTH Logi
cLev con
tact
Opentherm Logic level
contact of the zone
0 = Open
1 = Closed
2 = Off
Direct
zone
1
1
1
1
1
1
CP730
Zone Heat
up speed
Selection of heat up speed
of the zone
0 = Extra Slow
1 = Slowest
2 = Slower
3 = Normal
4 = Faster
5 = Fastest
Direct
zone
0
0
0
0
0
0
CP740
Zone cool
down speed
Selection of cool down
speed of the zone
0 = Slowest
1 = Slower
2 = Normal
3 = Faster
4 = Fastest
Direct
zone
0
0
0
0
0
0
CP780
Control
strategy
Selection of the control
strategy for the zone
0 = Automatic
1 = Room Temp.
based
2 = Outdoor Temp.
based
3 = Outdoor &
room based
Direct
zone
0
0
0
0
0
0
EP014
SCB func.
10V PWMin
Smart Control Board func
tion 10 Volt PWM input
0 = Off
1 = Temperature
control
2 = Power control
0-10 volt
input
0
0
0
0
0
0
GP007
Fan RPM
Max CH
Maximum fan speed dur
ing Central Heating mode
1000 - 8500 Rpm
Gas
fired ap
pliance
5200 5500 3500 3800 4300 4100
10 Settings
7762666 - v.02 - 29092020
C 340 / C 640