5.6
Reading out measured values
The various values measured by the appliance are displayed in the
#MEASURES
menu.
1. To access user level: Press the
>
key.
2. Select the menu
#MEASURES
.
4
Turn the rotary button to scroll through the menus or
modify a value.
4
Press the rotary button to access the menu selected
or confirm a value modification.
¼
For a detailed explanation of menu browsing, refer
to the chapter: "Browsing in the menus", page 66.
User level - #MEASURES menu
Parameter
Description
Unit
OUTSIDE TEMP.
Outside temperature
°C
ROOMTEMP. A
(1)
Room temperature of circuit A
°C
ROOMTEMP. B
(1)
Room temperature of circuit B
°C
ROOMTEMP. C
(1)
Room temperature of circuit C
°C
BOILER TEMP.
Water temperature in the boiler
°C
PRESSURE
Water pressure in the installation
bar
WATER TEMP.
(1)
Water temperature in the DHW tank
°C
INST DWH TEMP.
(1)
Instant hot water temperature
°C
STOR.TANK.TEMP
(1)
Water temperature in the storage tank
°C
DCW TEMPERATURE
(1)
Domestic cold water temperature
°C
SWIMMING P.T.B
(1)
Water temperature of the swimming pool on circuit B
°C
SWIMMING P.T.C
(1)
Water temperature of the swimming pool on circuit C
°C
OUTLET TEMP. B
(1)
Temperature of the flow water in circuit B
°C
OUTLET TEMP. C
(1)
Temperature of the flow water in circuit C
°C
SYSTEM TEMP.
(1)
Temperature of the system flow water if multi-generator
°C
T.DHW BOTTOM
(1)
Water temperature in the bottom of the DHW tank
°C
TEMP.TANK AUX
(1)
Water temperature in the second DHW tank connected to the AUX circuit °C
DHW A TEMP.
(1)
Water temperature in the second DHW tank connected to circuit A
°C
TEMP.SOL.TANK
(1)
Temperature of the hot water produced by solar power (TS)
°C
SOLAR.COLL.T.
(1)
Solar panel temperature (TC)
°C
SOLA.ENERGY
(1)
Solar energy accumulated in the tank
kWh
BACK TEMP
Temperature of the boiler return water
°C
WIND SPEED
Fan rotation speed
rpm
POWER
Instantaneous boiler output (0%: Burner off or running at minimum output) %
CURRENT
(µA)
Ionization current
µA
NB IMPULS.
Number of burner starts (not restartable)
The meter is incremented by 8 every 8 start-ups
RUNTIME
Number of burner operation hours (not restartable)
The meter is incremented by 2 every 2 hours
h
IN 0-10V
(1)
Voltage at input 0-10 V
V
(1) The parameter is only displayed for the options, circuits or sensors actually connected.
bar
1
1
2
2
r
c
STD
(
'
t
v
0
2
4
6
8
10
12
14
16
18
22
24
20
p
b
AUTO
x c
r
j
M
g
m
SUNDAY 11:45
C002219-D-04
AGC 10/15 - AGC 15 - AGC 25 - AGC 35
5. Commissioning
20/01/2012 - 300026081-001-B
81