Influence of the parameter setting CT.TEL on the I.TEL contact
CT.TEL I.TEL:
I.TEL: contact closed
I.TEL: contact open
CLOSE ANTIFR
The antifreeze mode is active on all boiler circuits.
The mode selected on the boiler is active.
0/1 A
The mode selected on the circuit is active.
The antifreeze mode is active on the circuit
concerned.
0/1 B
The mode selected on the circuit is active.
The antifreeze mode is active on the circuit
concerned.
0/1 C
The mode selected on the circuit is active.
The antifreeze mode is active on the circuit
concerned.
0/1 DHW
The mode selected on the DHW circuit is active.
The antifreeze mode is active for the DHW circuit.
0/1 AUX
4
The
M
AUX outlet on the connection terminal
block is active.
4
The boiler operates at a set point temperature
equal to
BOILER MAX
.
4
The
M
AUX outlet on the connection terminal
block is not active.
4
The boiler operates with a set point temperature
as a function of the outside temperature.
OPEN
ANTIFR
The mode selected on the boiler is active.
The antifreeze mode is active on all boiler circuits.
0/1 A
The antifreeze mode is active on the circuit
concerned.
The mode selected on the circuit is active.
0/1 B
The antifreeze mode is active on the circuit
concerned.
The mode selected on the circuit is active.
0/1 C
The antifreeze mode is active on the circuit
concerned.
The mode selected on the circuit is active.
0/1 DHW
The antifreeze mode is active for the DHW circuit.
The mode selected on the DHW circuit is active.
0/1 AUX
4
The
M
AUX outlet on the connection terminal
block is not active.
4
The boiler operates with a set point temperature
as a function of the outside temperature.
4
The
M
AUX outlet on the connection terminal
block is active.
4
The boiler operates at a set point temperature
equal to
BOILER MAX
.
5.5.3.
Naming the circuits and generators
1. Access the installer level: Press key
-
for around 5 seconds.
2. Select the menu
#NAMES OF THE CIRCUITS
.
4
Turn the rotary button to scroll through the menus or
modify a value.
4
Press the rotary button to access the menu selected
or confirm a value modification.
¼
For a detailed explanation of menu browsing, refer
to the chapter: "Browsing in the menus", page 66
1
1
2
2
r
c
STD
(
'
t
v
0
2
4
6
8
10
12
14
16
18
22
24
20
p
b
AUTO
x c
r
j
M
g
m
SUNDAY 11:45
5"
TEMP.: 68°
C002235-F-04
AGC 10/15 - AGC 15 - AGC 25 - AGC 35