5. Unscrew the 4 lateral holding screws.
6. Pivot the holder by 180°.
7. Screw the 4 lateral holding screws back in.
8. Follow in reverse order for re-assembly.
4
Do not disconnect the switch.
4
The switch remains on the panel and will therefore be
to the left of the control panel.
4.5
Hydraulic connections
4.5.1.
Flushing the system
Installation must be carried out in accordance with the prevailing
regulations, the codes of practice and the recommendations in these
instructions.
n
Fitting the appliance to new installations
4
Clean the installation with a universal cleaner to eliminate debris
from the appliance (copper, flaxen thread, flux).
4
Thoroughly flush the installation until the water runs clear and
shows no impurities.
n
Fitting the appliance to existing installations
4
Remove sludge from the installation.
4
Flush the installation.
4
Clean the installation with a universal cleaner to eliminate debris
from the appliance (copper, flaxen thread, flux).
4
Thoroughly flush the installation until the water runs clear and
shows no impurities.
M002523-B
180°
6
5
7
5
7
6
AGC 10/15 - AGC 15 - AGC 25 - AGC 35
4. Installation
20/01/2012 - 300026081-001-B
29