Q-Series
Change Transceivers
71
Changing X-band Circular Polarization
Prerequisites
Find a clean working environment that will not pollute the RF components.
Make sure that the Power Supply is disconnected from the source.
To switch between Left Hand Circular Polarization (LHCP) and Right Hand Circular Polariza-
tion (RHCP), disconnect and rotate the OMT/polarizer on the Q-Series.
Tools:
Hex wrench, 2.5 mm and 3 mm
1. Locate the OMT/Polarizer and using the Hex wrench, remove the eight (8) screws fastening it to
the feed system.
2. Using the Hex wrench, locate the eight (8) screws attaching the waveguides to the BUC and
partly remove them.
3. Using the Hex wrench, locate the eight (8) screws attaching the waveguides to the RF Filter and
partly remove them.
Do!
Disconnect the power to the Q-Seriesto avoid any damages to the equipment.
Warning!
The RF gaskets (O-ring) or feed system may be damaged if you fail to fol-
low the instructions below.
Summary of Contents for Q Series
Page 1: ...Instructions for Use Q Series Satellite Communications Terminal Manual Version 1 6...
Page 4: ...Q Series Instructions for Use 4 This page intentionally left blank...
Page 34: ...Operation Q Series 34 This page intentionally left blank...
Page 44: ...Q Series Admin Tool Q Series 44 This page intentionally left blank...
Page 48: ...Basic Maintenance Q Series 48 This page intentionally left blank...
Page 60: ...Mission Checklist Q Series 60 This page intentionally left blank...
Page 76: ...Change Transceivers Q Series 76 This page intentionally left blank...
Page 81: ...Q Series Surface Mounting Kit Option 81 Figure 48 Strapping the Q Series...
Page 82: ...Surface Mounting Kit Option Q Series 82 This page intentionally left blank...
Page 96: ...Alarms Q Series 96 This page intentionally left blank...
Page 103: ......