FEATURES FOR STAR MODELS ONLY
ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
311
Cradle Address Delimiter
This option specifies the delimiter character to be placed between the label data and
the cradle address when address stamping is enabled.
STAR System Speed
By default, the Reader and the Base exchange data at high speed over the wireless com
-
munication channel. Reducing the speed from high to low, the radio range can be fur
-
ther extended. Moreover, when using low speed, the Reader can be configured to use
the STAR Frequency Agility feature (see "
STAR Frequency Agility" on page 312
) also for
the 433 MHz model (see Table 9 on page 313).
To change the STAR System Speed, follow this procedure:
1. link the Reader to the Base;
2. scan the ENTER/EXIT PROGRAMMING MODE bar code above; read either the
“High speed” or “Low speed” programming label below to set the desired speed;
end by scanning the ENTER/EXIT bar code again.
3. place the Reader into the Base.
The Reader and the Base will now be linked at the new programmed speed.
This feature can also be programmed using the Datalogic Aladdin tool:
1. set the STAR System Speed to “High speed” or “Low speed” through Aladdin;
2. place an unlinked Reader into the Base.
The Reader and the Base will link at the new programmed speed.
NOTE: This feature only applies if "
Cradle Address Stamping" on page 310
enabled.
Set Cradle Address Delimiter Character
$CCNAD
To configure this feature, scan the ENTER/EXIT PRO
-
GRAMMING MODE bar code above, then the bar
code at left followed by two digits from the Alphanu
-
meric characters in
represent
-
ing your desired character(s). End by scanning the
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
Delimiter Character = 00 (no delimiter character)