CAMERA CONTROL
ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
125
Illumination Power Level (only for STD, HP, DC models)
With this parameter you can reduce the power of the illuminator. Beware that if there is
no alternative light source, this setting can worsen reading performance.
Mobile Phone Mode
This mode is useful for scanning bar codes displayed on a mobile phone. Other options
for this feature can be configured using the Datalogic Aladdin application.
$CIPWL64\r
Illumination Power Level = 100%
Illumination Power Level = Medium
$CIPWL32\r
$CIPWL0F\r
Illumination Power Level = Low
Illumination Power Level = Off
$CIPWL00\r
$CSNPE00
Mobile Phone Mode = Disable
Mobile Phone Mode = Enable
$CSNPE01
$CSNPE02
Mobile Phone Mode = Enhanced