SCANNING FEATURES
ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
115
Stand Mode/Object Detection Illumination Off Time
Specifies the amount of time reader illumination stays off after pulling the trigger when
in Stand Mode/Object Detection. The configurable range is 01 to 32 by 01 in increments
of 500ms (500ms to 16 seconds).
Illumination Intensity
With the following settings the illumination intensity can be reduced if needed. Not all
hardware versions support this function. Please contact Datalogic Technical Support for
more information.
Set Illumination OFF Time
$CSNTM
To configure, scan the ENTER/EXIT PROGRAMMING
MODE bar code above, then the bar code at left fol
-
lowed by the digits from the Alphanumeric charac
-
ters in
desired character(s). End by scanning the ENTER/
EXIT bar code.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
04 = Illumination OFF Time 1 second
$CIPWL64
Illumination Intensity and Frequency = Full Intensity
Illumination Intensity and Frequency = Medium Intensity
$CIPWL32
$CIPWL19
Illumination Intensity and Frequency = Low Intensity