FEATURES FOR STAR MODELS ONLY
ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
309
4 Digit Address Stamping
When address stamping is enabled, by default the device uses a 12 hex digit address.
es: 0000002139AE<Message>
With the following setting It is possible to reduce the address size at 4 digit in order to
be compatible with host working with this format. The address is not build in into the
scanner but must be configured manually by label programming during the installation.
It is responsibility of the installer to avoid duplicated address working with the same
base.
• This feature affects only the message format between Cradle and Host. Doesn't
impact the Radio protocol or procedure to link base and gun.
• In case "Ack from host is configured, the return message must have the same 4
digit address as a prefix.
• This feature is not recommended for new installation.
Enable Address Stamping and eventually address delimiter (See “Source Radio Address
Assign Unique Address to the Gun
Assign unique address to the gun as a character string in the range 0000 to 1999.
$CRF4E00
4 Digit Address Stamping = Disable
4 Digit Address Stamping = Enable
$CRF4E01
Assign Unique Address
$CRF4H
To configure this feature, scan the ENTER/EXIT PRO
-
GRAMMING MODE bar code above, then the bar
code at left followed by 4 couples of digits (in hex)
from the Alphanumeric characters in
representing your desired character(s). End
by scanning the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
Example: 1234 = 31323334