214
POWERSCAN™ PD/PM/PBT9600
BC412 Set Length 1
This feature specifies one of the bar code lengths for "
. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed
length if in Fixed Length Mode. Length includes the bar code’s data characters only.
The length can be set from 01 to 50 characters. See "
for more
detailed programming instructions.
BC412 Set Length 2
This feature specifies one of the bar code lengths for "
. Length 2 is the maximum label length if in Variable Length Mode, or the second
fixed length if in Fixed Length Mode. Length includes the bar code’s data characters
only.
The length can be set from 01 to 50 characters. A setting of 00 specifies to ignore this
length (only one fixed length). See "
for more detailed pro
-
gramming instructions.
Select BC412 Length 1 Setting
$CBCL1
To configure this feature, scan the ENTER/EXIT PRO
-
GRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu
-
-
ing your desired character(s). End by scanning the
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
Length 1 = 01 (one character)
Select BC412 Length 2 Setting
$CBCL2
To configure this feature, scan the ENTER/EXIT PRO
-
GRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu
-
-
ing your desired character(s). End by scanning the
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
Length 2 = 50 (50 characters)