POWERSCAN
™
BT8300
128
PowerScan™ BT8300 Family
5.2 Pen
Parameters
5.2.1
Minimum Output Pulse
This parameter sets the duration of the output pulse corresponding to the narrowest element in the barcode. In this way
the code resolution is controlled by the signal sent to the decoder, independently of the physical resolution of the code
read.
The shortest pulse (200
s) corresponds to a high-resolution code emulation and therefore a shorter transfer speed to the
decoder (for decoders able to work on high resolution codes). Likewise, longer pulses correspond to low-resolution code
emulation and therefore a longer transfer time to the decoder.
5.2.2
Conversion to Code 39 and Code 128
PowerScan™ BT8300 Series Readers
When using these readers it is possible to choose between converting the decoded codes into either Code 39 format or
Code 128 format. It is not possible to disable conversion.
5.2.3 Overflow
This parameter generates a white space before the first bar and after the last bar of the code. The selections are as
follows:
narrow
= space 10 times the minimum output pulse.
medium = space 20 times the minimum output pulse.
wide
= space 30 times the minimum output pulse.