POWERSCAN
™
BT8300
130
PowerScan™ BT8300 Family
5.3 Data
Format
For an overview of Message Formatting see Chapter 6.
5.3.1 Header/Terminator
Selection
The header/terminator selection is not effected by the reading of the restore default code. In fact, when the PowerScan
BT8300 connects with the BC 8030-BT, cradle header and terminator default values depend on the interface selection:
RS-232:
no header, terminator CR-LF
WEDGE:
no header, terminator ENTER
When the PowerScan BT8300 connects with a Bluetooth-Enabled PC, the reader header and terminator default values will
be:
SPP Profile: no header, terminator CR-LF
HID Profile: no header, terminator ENTER
When the PowerScan BT8300 connects with the BC 8030-BT the default values are usually restored through the reading
of RS-232 or WEDGE interface selection code. However, if the PowerScan BT8300 is connected with a Bluetooth-
Enabled PC it will NOT reset to default value when switched between Communication Types. In other words, the
PowerScan BT8300 can remember the setting of TERMINATOR. See chapter 2.
For the WEDGE interface, the following extended keyboard values can also be configured:
EXTENDED KEYBOARD TO HEX CONVERSION TABLE
IBM AT
IBM 3153
APPLE ADB
IBM XT
IBM 31xx, 32xx,
34xx, 37xx
Wyse
Digital
HEX KEY
KEY
KEY
KEY
83
ENTER ENTER
FIELD
EXIT
RETURN
84
TAB TAB TAB TAB
85
F1 F1 F1 F1
86
F2 F2 F2 F2
87
F3 F3 F3 F3
88
F4 F4 F4 F4
89
F5 F5 F5 F5
8A
F6 F6 F6 F6
8B
F7 F7 F7 F7
8C
F8 F8 F8 F8
8D
F9 F9 F9 F9
8E
F10 F10 F10 F10
8F
F11 ESC F11 F11
90
F12 BACKSPACE F12
F12
91
HOME HOME ENTER F13
92
END END
RESET F14
93
PG UP
PG UP
INSERT
F15
94
PG DOWN
PG DOWN
DELETE
F16
95
FIELD -
UP
96
FIELD +
DOWN
97
ENTER (Paddle)
LEFT
98
PRINT RIGHT
99
ESC ESC ESC
9A
CTRL (Right)
CTRL (Right)
CTRL (Right)
9B
Euro Space Space Space
For all devices using IBM AT (compatible) Wedge or USB-KBD interfaces, all values from
9C
to
FE
send the relative simulated keypress
when available or else the relative ALT-Mode sequence. See the Hex to Character Conversion Table in Appendix
C
.
For all devices using other Wedge interfaces, all values from
9C
to
FE
send the Space character.
Summary of Contents for PowerScan BT8300 Family