PROGRAMMING STRINGS
15
3
3.4 HOW TO ACCESS INSTALLER PARAMETERS
Set Right Parameter Description
The '
Set Right
' programming string allows the user to access some particular parameters
not available as standard user:
SR
<space>
L
<space>
PASSWORD
<CR><LF>
Where:
SR
:
'Set Right' command
L
:
Access Level Description
PASSWORD
: Password for the Level accessing
After entering this command, the device responds with the proper reply message and then
waits for one or more programming strings.
If the programming is correct, the device updates the configuration and confirms with the
following message:
Y
<space>
L
<CR><LF>
If programming contents are wrong (i.e. a typing error in the file) or due to a transmission
error, the device replies with the following message and programming data will not be
updated in this case:
N
<space>
ERRCODE
<CR><LF>
Where:
ERRCODE
:
Error Code (signed DEC value)
For information on Error Codes see the "Error Codes Table" in the Appendix.
NOTE
To set the
INSTALLER
level (the only one available outside the Datalogic
Company) use:
SR<space>1<space>STHD<CR><LF>