SPECIAL COMMANDS AND TABLES
65
A
A
SPECIAL COMMANDS AND TABLES
CONTROL RULES TABLE
This paragraph provides a list of the most important control rules that can be applied to the
6K and 8KA Family parameters.
PARAMETER CONTROL
RULES
CODE DEFINITION
Code Combination
Must be
Single Label
and
Code Collection
if
Host Application
Protocol Type
=
Crisplant
.
Must be
Standard Multi Label
and
Logical Combination
if
Operating Mode Selection
=
Continuous
.
Must be
Code Collection
if
No Read Message
=
Local No Read(s)
Message.
No Read Message
Must be
Local No Read(s) Message
if
Code Combination
=
Single
Label
.
Must be
Local No Read(s) Message
if
Code Combination
=
Code
Collection
.
Associate Same
Codes When
Coming From
Different Scanners
Not available if
Scanner Cluster Topology Role
Master
Synchronized
or
Master Multidata
.
CODE LABEL SETTINGS #N (DEPTH: n = 1 to 10)
Minimum Label
Length
Value must be
Maximum Label Length
Maximum Label
Length
Value must be
Minimum Label Length
Minimum Code
Position
Value must be
Maximum Code Position
Maximum Code
Position
Value must be
Minimum Code Position
OPERATING MODES
Operating Mode
Selection
Must be
Automatic
and
Continuous
if
Host Application Protocol
Type
Crisplant
.
Must be
Continuous
if
Code Combination
Single Label
.
Must be
Automatic
and
Continuous
if
Scanner Cluster Topology
Role
Master Synchronized
.
Must be
Automatic
and
Continuous
if
Scanner Cluster Topology
Role
Slave Synchronized
.
On Line Options
Must be
Serial On Line
if
Host Application Protocol Type
=
Crisplant
.
Stop Phase Edge
(only for On Line 2
Input)
Must be
Leading
if
Extended Phase
Enable
Summary of Contents for 6K-8KA FAMILY