6K-8KA FAMILY HOST MODE PROGRAMMING
16
3
3.5 SAVE AND RESTORE COMMANDS
The '
Data Storage
' programming command must have the following format:
E
<space>
MODE
<CR><LF>
Where:
E
:
Data Storage command.
MODE
:
Data Storage mode. The possible values are:
V
= Storage in temporary (volatile) memory only.
P
= Storage in temporary and permanent memory.
If the programming is correct, the device updates the configuration and confirms with the
following message:
Y
<space>
MODE
<CR><LF>
Where:
MODE
:
Data Storage mode.
CAUTION
Restart of the device is now forced. If no disconnection commands are sent
within a minimum timeout of 300 ms, the device will transmit the Self
Disconnection message (refer to the Paragraph 2.3).
If programming contents are wrong (i.e. a typing error in the file) or due to a transmission
error, the device replies with the following message and programming data will not be
updated in this case:
N
<space>
ERRCODE
<CR><LF>
Where:
ERRCODE
: Error Code (signed DEC value).
For information on Error Codes see the "Error Codes Table" in the Appendix.