PARAMETERS LIST
37
4
PARAMETER COMPLETE
PATH
SHC
PT
VALUE
Code EAN 8
/Layout/SlvPar/CodPar
/EAN8
145
1
0 = Disable
1 = Enable
Code UPC A
/Layout/SlvPar/CodPar
/UPCA
146
1
0 = Disable
1 = Enable
Code UPC E
/Layout/SlvPar/CodPar
/UPCE
147
1
0 = Disable
1 = Enable
EAN/UPC
ADD ON 2
/Layout/SlvPar/CodPar
/AddOn2
148
1
0 = Disable
1 = Enable
EAN/UPC
ADD ON 5
/Layout/SlvPar/CodPar
/AddOn5
149
1
0 = Disable
1 = Enable
CODE 3 OF 9 PARAMETERS
Decoding Severity
/Layout/SlvPar/CodPar
/Code39Par/DecSev
161
0
Range: 0 to 4
Check Digit
/Layout/SlvPar/CodPar
/Code39Par/ChkDgt
162
1
0 = Disable
1 = Enable
Length Type
/Layout/SlvPar/CodPar
/Code39Par/Lentyp
180
1
0 = Variable
1 = Fixed
CODE 3 OF 9 FIXED LENGTH #N (DEPTH: N = 1 to 12)
Fixed Length
/Layout/SlvPar/CodPar
/Code39Par/Digit#N
163
0
Range: 0 to 50
CODE 2 OF 5 INTERLEAVED PARAMETERS
Decoding Severity
/Layout/SlvPar/CodPar
/Code25Par/DecSev
164
0
Range: 0 to 4
Check Digit
/Layout/SlvPar/CodPar
/Code25Par/ChkDgt
165
1
0 = Disable
1 = Enable
Length Type
/Layout/SlvPar/CodPar
/Code25Par/Lentyp
181
1
0 = Variable
1 = Fixed
CODE2 OF 5 INTERLEAVED FIXED LENGTH #N (DEPTH: N = 1 to 12)
Fixed Length
/Layout/SlvPar/CodPar
/Code25Par/Digit#N
166
0
Range: 0 to 50
CODE 2 OF 5 COMPRESSED PARAMETERS
Decoding Severity
/Layout/SlvPar/CodPar
/Code25CmpPar
/DecSev
167
0
Range: 0 to 4
Check Digit
/Layout/SlvPar/CodPar
/Code25CmpPar/ChkDgt
168
1
0 = Disable
1 = Enable
Length Type
/Layout/SlvPar/CodPar
/Code25CmpPar/Lentyp
182
1
0 = Variable
1 = Fixed
CODE2 OF 5 COMPRESSED FIXED LENGTH #N (DEPTH: N = 1 to 12)
Fixed Length
/Layout/SlvPar/CodPar
/Code25CmpPar/Digit#N
169
0
Range: 0 to 50
CODABAR PARAMETERS
Check Digit
/Layout/SlvPar/CodPar
/CodBarPar/ChkDgt
170
1
0 = Disable
1 = Enable
Summary of Contents for 6K-8KA FAMILY
Page 1: ...6K 8KA FAMILY Host Mode Programming ...