PARAMETERS LIST
53
4
PARAMETER COMPLETE
PATH SHC
PT
VALUE
ETHERNET / SERVICES / MODBUS CLIENT
Status /Comms/Ethernet
/Services/ModbusClient
/Status
125
1
0 = Disable
1 = Enable
Data Tx
/Comms/Ethernet
/Services/ModbusClient
/ModbusC
-
1
0 = Disable
1 = Enable
Server Address
/Comms/Ethernet
/Services/ModbusClient
/Server_address
126
2
Max Length: 256
Start Register
Number
/Comms/Ethernet
/Services/ModbusClient
/Start_reg
127
0
Range: 0 to (231-1)
Number Of Registers /Comms/Ethernet
/Services/ModbusClient
/Num_reg
128
0
Range: 1 to (231-1)
ETHERNET / SERVICES / WEBSENTINEL CLIENT
Enable /Comms/Ethernet
/Services/SentinelClient
/Enable
-
1
0 = Disable
1 = Enable
WebSentinel Socket
/Comms/Ethernet
/Services/SentinelClient
/SentinelSocket
-
1
0 = Socket 1
1 = Socket 2
2 = Socket 3
Conveyor Speed
Check Type
/Comms/Ethernet
/Services/SentinelClient
/ConvSpeedCheck
/ConvSpeedCheckType
-
1
0 = Percent
1 = Absolute
Max Conveyor Speed
Percent Error (%)
/Comms/Ethernet
/Services/SentinelClient
/ConvSpeedCheck
/MaxConvSpeed
PercentError
-
0
Range: 0 to 20
Max Conveyor Speed
Absolute Error (mm/s)
/Comms/Ethernet
/Services/SentinelClient
/ConvSpeedCheck
/MaxConvSpeedAbs
Error
-
0
Range: 0 to 3000
Input timeout (secs)
/Comms/Ethernet
/Services/SentinelClient
/InputCheck
/InputTimeOut
-
0
Range: 3 to 10
Send
Autoconfiguration
Message
/Comms/Ethernet
/Services/SentinelClient
/SentineAuto
configurationMessage
-
1
0 = Disable
1 = Enable
Send Extended
Parcel Message
/Comms/Ethernet
/Services/SentinelClient
/SentinelExteNded
Parcel
-
1
0 = Disable
1 = Enable
Summary of Contents for 6K-8KA FAMILY
Page 1: ...6K 8KA FAMILY Host Mode Programming ...
Page 4: ...iv ...
Page 73: ...www datalogic com ...