6K-8KA FAMILY HOST MODE PROGRAMMING
36
4
PARAMETER COMPLETE
PATH
SHC
PT VALUE
6/8K SCANNER HYBRID SYSTEM SLAVE PARAMETERS / HEARTBEAT MSG
6/8K Scanner
Heartbeat Timeout
(sec)
/Operating/SLVHS/SLVHB
/SLVHBSockTimeOutHB
-
0
Range: 5 to 3600
4.3 READING SYSTEM LAYOUT
PARAMETER COMPLETE
PATH
SHC
PT
VALUE
READING SYSTEM LAYOUT
Device Assignment
/Layout/DevAssO
196
1
0 = Alone
1 = Master RS232
(Type A)
2 = Master Lonworks and
RS232 (Type A)
3 = Slave RS232
(Type A)
4 = Controller Lon Old8k
Number of Slaves
(Type A)
/Layout/NumSlSer
34
0
Range: 1 to 9
Number of LonWorks
Slaves
/Layout/NumSlOld8k
-
0
Range: 1 to 14
Number of LonWorks
Slaves
/Layout/NumSlNet
36
0
Range: 1 to 31
Display Installer Info
/Layout/ShowDbg
38
1
0 = Disable
1 = Enable
Modify&Backup Lon
Slave Configuration
/Layout/Update
64
1
0 = Disable
1 = Enable
Enable A.S.R.
/Layout/EnableASR
706
1
0 = Disable
1 = Enable
Motor Delay (ms)
/Layout/EnableASR
-
0
Range: 500 to 5000
LONWORKS SLAVES COMMON PARAMETERS (for backward compatibility)
CODE PARAMETERS
Code 3 of 9
/Layout/SlvPar/CodPar
/Cod39
140
1
0 = Disable
1 = Enable
Code 2 of 5
Interleaved
/Layout/SlvPar/CodPar
/Cod25
141
1
0 = Disable
1 = Enable
Code 2 of 5
Compressed
/Layout/SlvPar/CodPar
/Cod25Cmp
150
1
0 = Disable
1 = Enable
Code Codabar
/Layout/SlvPar/CodPar
/CodBar
152
1
0 = Disable
1 = Enable
Code 93
/Layout/SlvPar/CodPar
/Cod93
151
1
0 = Disable
1 = Enable
Code 128
/Layout/SlvPar/CodPar
/Cod128
142
1
0 = Disable
1 = Enable
Code EAN 128
/Layout/SlvPar/CodPar
/CodEAN128
143
1
0 = Disable
1 = Enable
Code EAN 13
/Layout/SlvPar/CodPar
/EAN13
144
1
0 = Disable
1 = Enable