Summary of Contents for GD4430-BK-B

Page 1: ...Gryphon I GD44XX General Purpose Corded Handheld Area Imager Bar Code Reader Quick Reference Guide ...

Page 2: ...ns may either be downloadable from the Datalogic website www scanning datalogic com or provided on appropriate media If you visit our website and would like to make comments or suggestions about this or other Datalogic publications please let us know via the Contact Datalogic page Disclaimer Datalogic has taken reasonable measures to provide informa tion in this manual that is complete and accurat...

Page 3: ...ar Codes 20 Configure Other Settings 20 Resetting Product Defaults 20 Reading Parameters 21 Aiming System 21 Good Read Green Spot Duration 21 Operating Modes 22 Scan Mode 22 Pick Mode 24 Multiple Label Reading 24 Technical Specifications 25 LED and Beeper Indications 28 Error Codes 31 Cleaning 32 Regulatory Information 33 Statement of Agency Compliance 33 FCC Class B Compliance Statement 33 FCC RF...

Page 4: ...NOTES ...

Page 5: ...lude any information that the receiv ing party can establish was 1 in the public domain 2 already in the receiving party s possession or rightfully known prior to receipt 3 rightfully learned from a third party not in violation of any other s proprietary rights or 4 indepen dently developed without access to Proprietary Information 1 4 Datalogic Product means the Datalogic Gryphon series scanner p...

Page 6: ...all take steps to protect the Proprietary Information no less securely than if it were End User s own intellectual property 5 3 The provisions of this Proprietary Information Section shall survive and continue for five 5 years after the termination of this Agreement 6 Limited Warranty 6 1 Datalogic warrants that under normal use and operation the Datalogic Product will conform substantially to the...

Page 7: ...GIC BE LIABLE TO END USER OR ANY THIRD PARTY FOR LOST PROFITS LOST DATA INTERRUPTION OF BUSINESS OR SERVICE OR FOR ANY OTHER SPECIAL CONSEQUENTIAL CONTINGENT INDIRECT INCIDENTAL PUNITIVE EXEMPLARY OR OTHER SIMILAR DAMAGES EVEN IF DATALOGIC HAS BEEN ADVISED OF THE POSSIBIL ITY OF SUCH DAMAGES 9 Government Restricted Rights International Use 9 1 Use duplication or disclosure of the Software by the U...

Page 8: ...ny of End User s assets are located 11 5 Attorneys Fees In the event an action is brought to enforce the terms and condi tions of this Agreement the prevailing party shall be entitled to reasonable attor neys fees both at trial and on appeal END Software Product Policy Datalogic reserves the right to ship its products with the latest version of software firmware available This provides our cus tom...

Page 9: ...portant Datalogic s exclusive patented Green Spot for good read feedback helps to improve productiv ity in noisy environments or in situations where silence is required When using the product with the cradle at a 45 position the aiming pattern can work as an aiming system to aid in position ing the bar code for quick and intuitive reading Decoding Reliably decodes all standard 1D linear and 2D bar...

Page 10: ... the Interface see page 8 3 Configure the Reader starting on page 20 optional depends on settings needed Connect Disconnect Cable to Reader Figure 1 Connecting to the Reader Host Connection The Gryphon plugs directly into the host de vice as shown in Figure 2 The power can also be supplied through an external power supply via the Interface Cable sup plied with a power jack Figure 2 Connecting to t...

Page 11: ...of view indicated by the aiming system will be smaller when the reader is closer to the bar code and larger when it is farther from the code Symbologies with smaller bars or elements mil size should be read closer to the unit Symbologies with larger bars or ele ments mil size should be read farther from the unit If the aiming system is centered and the entire bar code is within the aiming field yo...

Page 12: ...6XX Information and programming options for each interface type are provided in this section For defaults and additional infor mation associated with each interface proceed to the corre sponding chapter in the Gryphon 4400 PRG Configuring the Interface Scan the appropriate programming bar code to selects the in terface type for your system Unlike some other programming features and options interfa...

Page 13: ...ick Reference Guide 9 RS 232 RS 232 standard interface Select RS232 STD RS 232 Wincor Nixdorf Select RS232 WN RS 232 for use with OPOS UPOS JavaPOS Select RS 232 OPOS USB Com to simulate RS 232 standard interface Select USB COM STDa ...

Page 14: ...on I GD44XX IBM IBM 46xx Port 5B reader interface Select IBM P5B IBM 46xx Port 9B reader interface Select IBM P9B USB OEM USB OEM can be used for OPOS UPOS JavaPOS Select USB OEM a Download the correct USB Com driver from www datalogic com ...

Page 15: ...T PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Standard Key Encoding Select KBD AT Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard Select KBD AT NK AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Alternate Key Select KBD AT ALT Keyboard Wedge for IBM AT PS2 with alternate key encoding but without external keyboard Select KBD AT ALT NK ...

Page 16: ...erminal 3153 Select KBD IBM 3153 Keyboard Wedge for IBM Terminals 31xx 32xx 34xx 37xx make only keyboard Select KBD IBM M Keyboard Wedge for IBM Terminals 31xx 32xx 34xx 37xx make break keyboard Select KBD IBM MB USB Keyboard with alternate key encoding Select USB Alternate Keyboard USB Keyboard for Apple computers Select USB KBD APPLE ...

Page 17: ...70 80 90 95 w Std Key Encoding Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 without Alternate Key Keyboard Wedge for IBM AT PS2 without alternate key encoding but without external keyboard All other interfaces support ONLY the following Country Modes U S Belgium Britain France Germany Italy Spain Sweden KEYBOARD ...

Page 18: ...e Type 14 Gryphon I GD44XX COUNTRY MODE ENTER EXIT PROGRAMMING MODE Country Mode U S Country Mode Belgium Country Mode Britain Country Mode Croatia Supports only the interfaces listed in the Country Mode feature description ...

Page 19: ...eference Guide 15 COUNTRY MODE Continued Country Mode Czech Country Mode Denmark Country Mode France Country Mode Germany Country Mode Hungary Country Mode Italy Supports only the interfaces listed in the Country Mode feature description ...

Page 20: ... I GD44XX COUNTRY MODE Continued Country Mode Japanese 106 key Country Mode Norway Country Mode Poland Country Mode Portugal Country Mode Romania Country Mode Spain Supports only the interfaces listed in the Country Mode feature description ...

Page 21: ... the Interface Type Quick Reference Guide 17 COUNTRY MODE Continued Country Mode Sweden Country Mode Slovakia Country Mode Switzerland Supports only the interfaces listed in the Country Mode feature description ...

Page 22: ...he format in which the reader sends character data This applies to keyboard wedge interfaces This does not apply when an alternate key encoding keyboard is se lected ENTER EXIT PROGRAMMING MODE Caps Lock State Caps Lock OFF Caps Lock State Caps Lock ON Caps Lock State AUTO Caps Lock Enable ...

Page 23: ...ption specifies the setting of the Numbers Lock Num lock key while in keyboard wedge interface This only applies to alternate key encoding interfaces It does not apply to USB keyboard ENTER EXIT PROGRAMMING MODE Numlock Numlock key unchanged Numlock Numlock key toggled ...

Page 24: ... code once to enter Programming Mode scan the desired parameter settings scan the ENTER EXIT bar code again to accept your changes which exits Programming Mode and re turns the reader to normal operation Configure Other Settings Additional programming bar codes are available in the PRG to allow for customizing programming features If your installa tion requires different programming than the stand...

Page 25: ...isition The illuminator will remain on until the symbol is decoded As you read code symbols adjust the distance at which you are holding the reader Aiming System A number of options for customizing control of the Aiming System are available See the Gryphon I GD44XX PRG for more information and programming bar codes Good Read Green Spot Duration Successful reading can be signaled by a good read gre...

Page 26: ...pulled again or until the programmable maximum scan on time 1 has elapsed Reading a label does not disable scan ning Double Read Timeout1 prevents undesired multiple reads while in this mode Trigger Hold Multiple When the trigger is pulled scanning starts and the product scans until the trigger is released or maximum scan on time 1 has elapsed Reading a label does not disable scanning Double Read ...

Page 27: ...ead occurs The scanner exits stand mode when movement is detected If the trigger is activated from stand mode the scanner transitions into one of the triggered modes ENTER EXIT PROGRAMMING MODE Scan Mode Trigger Single Scan Mode Trigger Pulse Multiple Scan Mode Trigger Hold Multiple Scan Mode Flashing Scan Mode Always On Scan Mode Stand Mode ...

Page 28: ...r transmitted to the host It is active only while the scanner is in Trigger Single mode If the scanner switches to a different Read Mode Pick Mode is automatically disabled Multiple Label Reading The reader offers a number of options for multiple label read ing See the PRG or software configuration tool for descrip tions of these features and programming labels This feature is not compatible with ...

Page 29: ... 181mm Length3 9 100mm Width2 8 71mm Weight withoutcable Approximately6 9ounces 195 6g Electrical Characteristics Voltage Current InputVoltage GD441X 4 0 14 0VDC GD443X 4 2 5 25VDC Operating typical GD441X 170ma GD443X 160ma Operating max GD441X 385ma GD443X 350ma Idle standby typical GD441X 65ma GD443X 65ma Performance Characteristics LightSource LEDs Roll Tilt Tolerance Upto 180 PitchTolerance 4...

Page 30: ... 5 40cm 7 5mil 0 5 0 12 7cm 13mil 43 6 8 1 1 17 2cm PDF 417 6 6mil 1 0 5 9 2 5 15cm 10mil 0 2 8 6 0 5 22cm 15mil 0 6 13 4 1 5 34cm 4mil 0 7 2 7 1 8 6 8cm 6 6mil 0 1 4 4 0 1 11 2cm 10mil 0 5 6 0 14 3cm DataMatrix 10mil 0 8 to6 3 2 0 16cm 15mil 0 to9 3 0 23 6cm 5mil 1 1 2 4 2 8 6 1cm QRCode 10mil 1 2 to4 9 3 0 12 5cm 15mil 0 4 to7 5 1 0 19cm 6 7mil 0 8 1 7 2 1 4 2cm Minimum ElementWidth Standard Ran...

Page 31: ...ingparameters NormalorInverted SquareorRectangularStyle Datalength 1 3600characters Maxicode QRCodes QR MicroQRandMultipleQRCodes Aztec PostalCodes AustralianPost Japa nesePost KIXPost PlanetCode Postnet RoyalMailCode RM45CC IntelligentMailBarcode IMB SwedenPost PortugalPost LaPosteA R39 4 StateCanada PDF 417 MacroPDF MicroPDF417 GS1Composites 1 12 CodablockF FrenchCIP13a GS1DataBarStacked GS1 Dat...

Page 32: ... NorthAmerica FCC Part15ClassB Canada IC ICES 003ClassB Russia Gost EuropeanUnionEMCDirective VCCI Japan KoreanKCC TaiwanEMC BSMI Australia ACMA LaserClassSafety IECClass2 Radiation1mWAvg Emittedwavelength650nm 12ms pulse BeamDivergence8 4degx8 1deg plus pattern ComplieswithFDAperformancestandardsforlaserproductsexceptfordeviationspursuantto LaserNoticeNo 50 datedJune24 2007 Indicator Description ...

Page 33: ...olume ReaderActive Mode Thereaderisactive andreadytoscan The LED is lit steadilya N A Reader Disabled Thereaderhasbeen disabledbythe host TheLEDblinks continuously N A GreenSpota flashes momentarily Uponsuccessful readofalabel the softwareshallturn thegreenspoton forthetimespeci fiedbytheconfig uredvalue N A N A ImageCapture Whenreadytocap tureimage Blue light flashes 2 times when updating N A a E...

Page 34: ...ur rentvolume LabelProgram mingMode Acceptanceof PartialLabel Incaseswheremulti plelabelsmustbe scannedtoprogram onefeature thisindica tionacknowledges eachportionasitissuc cessfullyscanned N A Readersounds oneshortbeepat highestfre quencyandcur rentvolume LabelProgram mingMode Acceptanceof Programming Configurationoption s havebeensuccessfully programmedvialabels andthereaderhas exitedProgramming...

Page 35: ...ld Replaceable Unit isolation mode If the reader is reset the sequence will be repeated Press and release the trig ger to hear the FRU indication code The following table describes the LED flashes beep codes as sociated with an error found Number of LED Flashes Beeps Error Corrective Action 1 Configuration Contact Helpdesk for assistance 2 Interface PCB 6 Digital PCB 11 Imager ...

Page 36: ...t performance during scanning operations Always use a soft lint free cloth or lens tissue dampened with isopropyl alcohol or equivalent or water based window cleaner A cotton swab may be used in hard to reach areas CAUTION Do not use abrasive cleansing agents or abrasive pads to clean scan windows or plastics Do not spray or pour liquids directly onto the unit ...

Page 37: ...nt has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential instal lation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interfe...

Page 38: ...e present appareil numerique n emet pas de bruits radioelec triques depassant les limites applicables aux appareils nume riques de la classe B prescrites dans le Reglement sur le brouillage radioelectrique edicte par le ministere des Commu nications du Canada Power Supply This device is intended to be connected to a UL Listed CSA Certified computer which supplies power directly to the read er or e...

Page 39: ... of the Scanner and is shown below N26 3 See prod uct man ual and pack age for pate nt listin g ACC ESSO RY LIST ED I T E 3KR U Scanner Regulatory Label DO NOT STARE INTO BEAM See Pkg for patent listing LASER LIGHT DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT OUTPUT RADIATION 1 mW AVG EMITTED WAVE LENGTH 650 nm 12 ms PULSE IEC60825 1 2007 CAUTION CLASS 2 LASER LIGHT WHEN OPEN AVOID EXPOSURE LASER ...

Page 40: ...BLE À L OEIL NU ET IL EST ÉMIS PAR LA FENÊTRE DÉSIGNÉE SUR L ILLUSTRA TION DANS LA FIGURE ALUZLÁSERES VISIBLE AL OJO HUMANO Y ES EMITIDA POR LA VENTANA INDICADA EN LA FIGURA LUCE LASER NON FISSARE IL FASCIO APPAREC CHIOLASERDI CLASSE 2 MASSIMA POTENZA D USCITA LUNGHEZZA D ONDA EMESSA CONFORME A EN 60825 1 2007 LASERSTRAHLUNG NICHT IN DEN STRAHL BLICKEN PRODUKT DER LASERKLASSE 2 MAXIMALE AUS GANGSL...

Page 41: ...ivi di installazione utilizzo o manutenzione Il prodotto utilizza un diodo laser a bassa potenza Sebbene non siano noti danni riportati dall occhio umano in seguito ad una esposizione di breve durata evitare di fissare il raggio laser così come si eviterebbe qualsiasi altra sorgente di luminosità intensa ad esempio il sole Evitare inoltre di dirigere il raggio laser negli occhi di un osservatore a...

Page 42: ...LASER Ce produit est conforme aux normes de sécurité laser en vi gueur à sa date de fabrication CDRH 21 CFR 1040 et EN 60825 1 Il n est pas nécessaire d ouvrir l appareil pour l installation l utilisation ou l entretien Le produit utilise une diode laser Aucun dommage aux yeux humains n a été constaté à la suite d une exposition au rayon laser Eviter de regarder fixement le rayon comme toute autre...

Page 43: ...a un diodo láser a baja potencia No son noto rios daños a los ojos humanos a consecuencia de una ex posición de corta duración Eviten de mirar fijo el rayo láser así como evitarían cualquiera otra fuente de luminosidad intensa por ejemplo el sol Además eviten de dirigir el rayo láser hacia los ojos de un observador también a través de superficies re flectantes como los espejos ATENCIÓN La utilizac...

Page 44: ...nenzurEntsorgung von Elektro undElektronik Altgeräten WEEE erhalten Sie auf der Webseite www scanning datalogic com Spanish Si desea información acerca de los procedimientos para el desecho de los residuos del equipo eléctrico y electrónico WEEE visite la página Web www scanning datalogic com Portuguese Para informações sobre a disposição de Sucatagem de Equipamentos Elétricos e Eletrônicos WEEE W...

Page 45: ...de product maintenance including but not limited to cleaning of the upper window in accordance with product manual installation or service of product by other than Dat alogic representatives use of product with any other instrument equipment or appa ratus modification or alteration of product External cables and replacement of upper window cartridge due to scratching stains or other degradation wi...

Page 46: ...t page where you can download specific Manuals and Software Utilities including Datalogic Aladdin a multi platform utility program that allows device configuration using a PC It provides RS 232 interface configuration as well as configuration bar code printing Service Support Technical Support Product documentation and program ming guides and Technical Support Department in the world Service Progr...

Page 47: ...ióndelasleyesdelosPaísesMiembrosrespectoa lacompatibilidadelectro magnéticaylasMedidasdeseguridad relativasalproducto Questadichiarazioneèbasata sullaconformità deiprodottialle norme seguenti Thisdeclaration isbased uponcompliance oftheproductsto the following standards Cettedéclarationreposesur la conformité desproduitsauxnormessuivantes DieseErklärungbasiertdarauf daßdasProduktdenfolgendenNormen...

Page 48: ...pan Datalogic Scanning KK Telephone 81 0 3 3491 6761 japan scanning datalogic com Latin America Datalogic Scanning Inc Telephone 305 742 2206 latinamerica scanning datalogic com Singapore Datalogic Scanning Singapore PTE LTD Telephone 65 6435 1311 singapore scanning datalogic com Iberia Datalogic Scanning SAS Sucursal en España Telephone 34 91 746 28 60 spain scanning datalogic com United Kingdom ...