Support and Warranty
Soporte y garantía
www.schlage.com/support www.schlage.com/support
(877) 671-7011
+1 512-712-1316
+1 512-712-1316
23940620
ULC-S319 compliance is no longer valid when
any add-on, expansion, memory, or other module
manufactured or supplied by the manufacturer or
manufacturer's representative is used. ULC-S319
Listed PSU must be used for Canadian installations.
FCC Statement
This device complies with part 15 of the FCC rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference,
and (2) this device must accept any interference
received, including interference that may cause
undesired operation.
Changes or modifi cations to this equipment not
expressly approved by Ingersoll Rand could void the
user’s authority to operate the equipment.
Industry Canada Statement:
This device complies with Industry Canada licence-
exempt RSS standard(s). Operation is subject to
the following two conditions: (1) this device may
not cause interference, and (2) this device must
accept any interference, including interference that
may cause undesired operation of the device. This
Class A digital apparatus complies with Canadian
ICES-003.
El certifi cación LUC-S319 deja de ser válida cuando
se usa cualquier agregado, expansión, memoria u
otro módulo fabricado o provisto por el fabricante o
el representante del fabricante.
Declaraciones de la FCC
Este dispositivo cumple con la Sección 15 de las
normas de la CCF. La utilización está sujeta a las
siguientes dos condiciones: (1) Este dispositivo
no puede causar interferencia dañina y (2) este
dispositivo debe aceptar cualquier interferencia
recibida, incluyendo interferencia que pueda causar
un funcionamiento indeseado.
Los cambios o modifi caciones a este equipo sin
autorización expresa de Schlage podrían anular la
autoridad del usuario para utilizar el equipo.
Declaraciones de Industry Canada
Este dispositivo cumple con los estándares RSS de
licencia exenta de Industry Canada. Su utilización
está sujeta a las siguientes dos condiciones: (1)
este dispositivo no puede causar interferencia
y (2) este dispositivo debe aceptar cualquier
interferencia, incluyendo interferencia que pueda
causar un funcionamiento no deseado. Este aparato
digital Clase A cumple con la ICES-003 canadiense.
RS485 connection shall not be used in S319
applications until a compatible S319 panel is
identifi ed with RS485 communications.
La conexión RS485 no debe utilizarse en
aplicaciones S319 hasta que se identifi que un panel
S319 compatible con comunicaciones RS485.
1
Locate and/or install single
gang box.
Ubique o instale la caja de
banda única.
2
Wire the cable to the control
module.
Conecte el cable al módulo
de control.
A power limited, class 2 UL 294
approved power supply must be used.
Voltage rating: 5V to 16V
Una fuente de poder limitada, clase 2
UL 294 debe ser utilizada.
Rango de tensión: 5 V a 16 V
Max. Length to Panel
Long. máx. al panel
Length
AWG
Longitud AWG
200' (60 m)
22
60 m
22
300' (90 m)
20
90 m
20
500' (150 m)
18
150 m
18
Current @ 12V and 25C
Corriente a 12 V y 25 C
Model
Avg. mA
Max. mA
Modelo
Promedio
de mA
Máximo
de mA
MT15,
MT15-485
120
200 MT15,
MT15-485
120
200
MTK15,
MTK15-485
120
230
MTK15,
MTK15-485
120
230
Cable Connections
Conexiones de cables
Black
Ground
Negro
Tierra
Blue
Unused
Azul
Sin uso
Brown
Red LED Control
Marrón
Control de LED rojo
Gray**
Tamper Out
Gris**
Manipulación
Green
Wiegand Data 0 / Data
Verde
Datos Wiegand 0 / Datos
Orange
Green LED Control
Anaranjado Control de LED verde
Pink*
RS485-A/Y
Rosa*
RS485-A/Y
Red
Power In
Rojo
Encendido
Shield
Shield Ground
Blindado
Descarga del blindaje
Tan*
RS485-B/Z
Habano*
RS485-B/Z
White
Wiegand Data 1 / Clock
Blanco
Datos Wiegand 1 / Reloj
Yellow
Beeper Control
Amarillo
Control de alerta sonora
Consult
manufacturer's
instructions for
installation.
Consulte las
instrucciones del
fabricante para la
instalación.
6
Install case.
Instale la carcasa.
In case of alternative
mounting screws, only a
#6 diameter Pan Head
Screw should be used.
En caso de que se
necesiten tornillos de
montaje alternativos,
solo deben utilizarse
tornillos de cabeza
troncocónica de
diámetro N° 6.
7
Snap cover into place and
install cover screw.
Coloque la cubierta en su
lugar e instale el tornillo de la
cubierta.
TEST
PRUEBA
a
Power the reader.
The LED will light followed by a
beeper tone. This indicates that the
reader is ready.
If LED and beeper do not respond,
check cable connections.
Encienda el lector.
Se encenderá el LED seguido de
un tono de alerta sonora. Eso indica
que el lector está preparado.
Si el LED y la alerta sonora no
responden, verifi que las conexiones
de los cables.
b
Present a proper card or
token programmed to operate
the reader.
Presente una tarjeta
apropiada o una clave
programada para operar el
lector.
LED Indicators
Indicadores de LED
Green Card was read and
accepted
Verde Se leyó y aceptó la tarjeta
Red
Card was read but not
accepted (does not indicate
faulty installation)
Rojo
Se leyó la tarjeta, pero no se
aceptó (no indica que haya
una instalación defectuosa)
Do not
over-tighten!
¡No apriete
demasiado!
Tamper
Resistant
6-32
x
¹⁄₄
"
Pin-in-Torx button
head, Use if
desired.
Resistente a la
manipulación
Perno de cabeza
semiesférica Pin-
in-Torx de 6-32 x
¹⁄₄
", Utilícelo si lo
desea.
Regular
6-32 x
¹⁄₄
"
Regular
6-32 x
¹⁄₄
"
BASEPLATE OPTION
OPCIÓN DE PLACA BASE
i
Install baseplate.
Instale la placa base.
ii
Install case.
Instale la carcasa.
Use this option for
more robust tamper
resistance.
Continue to step 5
after completing this
step.
Utilice esta opción
para obtener una
resistencia a la
manipulación más
intensa.
Luego de completar
este paso, continúe
en el paso 5.
This step replaces
step 6.
Este paso reemplaza
al paso 6.
3
Route cable through box.
Pase el cable a través de la
caja.
4
See BASEPLATE OPTION
section before continuing.
Antes de continuar, consulte
la sección OPCIÓN DE
PLACA BASE.
5
Plug cable into case.
Enchufe el cable en la
carcasa.
MT15
Multi-Technology Reader—
Single-Gang
Lector multitecnológico—
Banda única
MTK15
Multi-Techology Reader with
Keypad— Single-Gang
Lector multitecnológico con
teclado— Banda única
SINGLE GANG READER
INSTALLATION INSTRUCTIONS
MODELS
MT15, MT15-485, MTK15, MTK15-485
LECTOR DE BANDA ÚNICA
INSTRUCCIONES DE INSTALACIÓN
MODELOS MT15, MT15-485, MTK15, MTK15-485
Tools
• Phillips Screwdriver
• 6-32 Tap
• 1" (25 mm),
¹⁄₈
" (3 mm) Drill Bits
• T10 Security Torx™ Bit (Optional)
Herramientas
• Desatornillador Phillips
• Macho de roscar de 6-32
• Brocas de 1" (25 mm),
¹⁄₈
" (3 mm)
• Mecha T10 Security Torx™
(Opcional)
For Indoor/Outdoor Use
Para uso en interiores/exteriores
* These wires are unused for readers that do not support RS485 communication.
** Tamper Outputs are to be connected to a UL Burglary System.
* Estos cables no se utilizan para lectores que no admiten la comunicación RS485.
** Las salidas de sabotaje se deben conectar a un sistema antirrobo con certifi cación UL.