D a t a D i r e c t N e t w o r k s S 2 A 9 5 5 0 U s e r G u i d e
R e m o t e M a n a g e m e n t o f S 2 A 9 5 5 0
5.
Decide whether the SNMP functionality should be enabled. To enable or disable SNMP, use the
appropriate version of the command:
NETWORK SNMP=ON|OFF.
NOTE :
If you are using directMONITOR (the external system console option) with the S2A9550, the
SNMP function should be enabled.
6.
If the SNMP function is enabled,
enter the IP address of the computer to be used to monitor
the SNMP traps:
NETWORK TRAPIP=<computer’s IP address>
.
7.
Decide whether the Syslog capability should be enabled. To enable or disable, use the
appropriate version of the command:
NETWORK SYSLOG=ON|OFF
.
NOTE :
If you are using directMONITOR (the external system console) with the S2A9550, the syslog
function should be enabled.
8.
If the SYSLOG function is enabled,
enter the destination IP address for the Syslog packets:
NETWORK SYSLOGIP=<destination IP address>.
Ensure your destination computer supports
the SYSLOG feature. For example, on UNIX systems, the SYSLOGD application must be
properly installed and running.
9.
The default destination port number for Syslog packets is 514. If you need to change it, use the
command:
NETWORK SYSLOGPORT=<port number>.
10.
Set up the routing table which describes how the S2A9550 can communicate with the hosts on
other networks. Use the
ROUTE
command to display the current settings
.
- To set the current gateway in the network routing table to the specified Internet address:
ROUTE GATEWAY=<aaa.bbb.ccc.ddd>
- To delete gateways from the routing table:
ROUTE DEL=<aaa.bbb.ccc.ddd>
GATEWAY=<aaa.bbb.ccc.ddd>
- Add new gateway to the table:
ROUTE ADD=<aaa.bbb.ccc.ddd>
GATEWAY=<aaa.bbb.ccc.ddd>
Figure 3-67 Current Network Configuration Screen
Network Configuration
S2A [1]: network
=====================
Gateway: 172.16.0.254
Netmask: 255.255.255.0
MAC Address Unit #1: 00:01:ff:01:00:ae
IP Address Unit #1: 172.16.0.1
IP Address Unit #2: -- Unknown --
Services
--------
Telnet: ENABLED
Telnet Port Unit #1: 23
Telnet Port Unit #2: 23
API Server: ENABLED
API Server Port Unit #1: 8008
API Server Port Unit #2: 8009
SNMP: ENABLED
SNMP Trap IP Address: 0.0.0.0
Limited SNMP: DISABLED
Syslog: ENABLED
Syslog IP Address: 172.16.0.253
Syslog Port Unit #1: 514
Syslog Port Unit #2: 514
Summary of Contents for S2A9550
Page 1: ...DataDirect Networks Silicon Storage Appliance S2A9550 User Guide Rev 4 0 ...
Page 13: ...SECTION 1 Introducing the S2A9550 ...
Page 14: ...This page intentionally left blank ...
Page 21: ...SECTION 2 Installing the S2A9550 ...
Page 22: ...This page intentionally left blank ...
Page 24: ...Installation 12 DataDirect Networks S2A 9550 User Guide This page is intentionally blank ...
Page 43: ...SECTION 3 Using the S2A9550 Management Administrative Facilities ...
Page 44: ...This page intentionally left blank ...
Page 93: ...SECTION 4 Supporting the S2A9550 ...
Page 94: ...This page intentionally left blank ...
Page 113: ...SECTION 5 Appendices ...