Installation
30
DataDirect Networks S2A 9550 User Guide
One zoning configuration is supported for each of the host ports. Any unauthorized user
accessing the S2A storage is considered “anonymous” and granted the Zoning access for
the host port to which they are connected. Given below is an example for adding LUN
zoning to host port 1. External LUN 1 is mapped to internal LUN 0 and it is read-only for
the users.
1.
To edit the default zoning on a host port, use the command:
zoning edit
<Enter>
. The
current settings are displayed (
2.
Select a host port (1..4):
1
<Enter>
3.
Then specify the internal LUN (0..127) to be mapped to the external LUN. In this
example, the settings should be:
External LUN 0 is not mapped. New internal LUN: n
External LUN 1 is not mapped. New internal LUN: R0
External LUN 2 is not mapped. New internal LUN: q
The new settings are displayed (
.
4.
Repeat the above steps to configure other host ports.
NOTE :
The S2A9550 installation is complete at this point. Your client systems should now
be able to access the LUNs on the S2A9550. If you want to remotely monitor the S2A9550,
please refer to Section 3.9 for information on how to configure the network interface settings.
Anonymous Access (host port zoning) only provides the
minimum level of security.
!
Warning
LUN Zoning
-----------------------------------------------------------------------------
Enter the host port (1..4), ‘q’ to quit.
Figure 2-16 Zoning Configuration Screen
S2A [1]: zoning edit
World Wide Name
Port
External LUN, Internal LUN
1
1
<enter>
Enter the new LUN zoning for this host port.
For each external LUN specify the internal LUN the user will have access
Specify the internal LUN (0..127), or ‘n’ for none or ‘q’ to quit.
External LUN 0 is not mapped. New internal LUN:
n
<enter>
21000001FF040004
2
22000001FF040004
3
23000001FF040004
4
24000001FF040004
to. ‘R’ preceding the LUN indicates the LUN will be read-only for the user.
Enter ‘P’ indicates a place holder LUN that will have zero capacity.
Enter ‘n’ for no LUN or ‘q’ to quit.
External LUN 1 is not mapped. New internal LUN:
R0
<enter>
LUN Zoning
-----------------------------------------------------------------------------
World Wide Name
Port
External LUN, Internal LUN
1
21000001FF040004
2
22000001FF040004
3
23000001FF040004
4
24000001FF040004
R001,000
Zoning changed on host port 1.
External LUN 2 is not mapped. New internal LUN:
e
<enter>
Summary of Contents for S2A9550
Page 1: ...DataDirect Networks Silicon Storage Appliance S2A9550 User Guide Rev 4 0 ...
Page 13: ...SECTION 1 Introducing the S2A9550 ...
Page 14: ...This page intentionally left blank ...
Page 21: ...SECTION 2 Installing the S2A9550 ...
Page 22: ...This page intentionally left blank ...
Page 24: ...Installation 12 DataDirect Networks S2A 9550 User Guide This page is intentionally blank ...
Page 43: ...SECTION 3 Using the S2A9550 Management Administrative Facilities ...
Page 44: ...This page intentionally left blank ...
Page 93: ...SECTION 4 Supporting the S2A9550 ...
Page 94: ...This page intentionally left blank ...
Page 113: ...SECTION 5 Appendices ...