13-0*
SLC
Settings
13-00
SL
Controller
Mode
13-01
Start
Event
13-02
Stop
Event
13-03
Reset
SLC
13-1*
Comparators
13-10
Comparator
Operand
13-11
Comparator
Operator
13-12
Comparator
Value
13-2*
Timers
13-20
SL
Controller
Timer
13-4*
Logic
Rules
13-40
Logic
Rule
Boolean
1
13-41
Logic
Rule
Operator
1
13-42
Logic
Rule
Boolean
2
13-43
Logic
Rule
Operator
2
13-44
Logic
Rule
Boolean
3
13-5*
States
13-51
SL
Controller
Event
13-52
SL
Controller
Action
14-**
Special
Functions
14-0*
Inverter
Switching
14-00
Switching
Pattern
14-01
Switching
Frequency
14-03
Overmodulation
14-04
PWM
Random
14-06
Dead
Time
Compensation
14-1*
Mains
On/Off
14-10
Line
Failure
14-11
AC
line
voltage
at
line
power
fault
14-12
Function
at
Line
power
Imbalance
14-13
LIne
Failure
Step
Factor
14-14
Kin.
Backup
Timeout
14-2*
Trip
Reset
14-20
Reset
Mode
14-21
Automatic
Restart
Time
14-22
Operation
Mode
14-23
Typecode
Setting
14-24
Trip
Delay
at
Current
Limit
14-25
Trip
Delay
at
Torque
Limit
14-26
Trip
Delay
at
Inverter
Fault
14-28
Production
Settings
14-29
Service
Code
14-3*
Current
Limit
Ctrl.
14-30
Current
Lim
Ctrl,
Proportional
Gain
14-31
Current
Lim
Ctrl,
Integration
Time
14-32
Current
Lim
Ctrl,
Filter
Time
14-35
Stall
Protection
14-4*
Energy
Optimizing
14-40
VT
Level
14-41
AEO
Minimum
Magnetization
14-42
Minimum
AEO
Frequency
14-43
Motor
Cos-Phi
14-5*
Environment
14-50
RFI
Filter
14-51
DC
Link
Compensation
14-52
Fan
Control
14-53
Fan
Monitor
14-55
Output
Filter
14-56
Capacitance
Output
Filter
14-57
Inductance
Output
Filter
14-59
Actual
Number
of
Inverter
Units
14-7*
Compatibility
14-72
Legacy
Alarm
Word
14-73
Legacy
Warning
Word
14-74
Leg.
Ext.
Status
Word
14-8*
Options
14-80
Option
Supplied
by
External
24VDC
14-89
Option
Detection
14-9*
Fault
Settings
14-90
Fault
Level
15-**
Drive
Information
15-0*
Operating
Data
15-00
Operating
Hours
15-01
Running
Hours
15-02
kWh
Counter
15-03
Power-ups
15-04
Over
Temps
15-05
Over
Volts
15-06
Reset
kWh
Counter
15-07
Reset
Running
Hours
Counter
15-1*
Data
Log
Settings
15-10
Logging
Source
15-11
Logging
Interval
15-12
Trigger
Event
15-13
Logging
Mode
15-14
Samples
Before
Trigger
15-2*
Historic
Log
15-20
Historic
Log:
Event
15-21
Historic
Log:
Value
15–22
Historic
Log:
Time
15-3*
Fault
Log
15-30
Fault
Log:
Error
Code
15-31
Fault
Log:
Value
15-32
Fault
Log:
Time
15-4*
Drive
Identification
15-40
FC
Type
15-41
Power
Section
15-42
Voltage
15-43
Software
Version
15-44
Ordered
Typecode
String
15-45
Actual
Typecode
String
15-46
Frequency
Converter
Ordering
No
15-47
Power
Card
Ordering
No
15-48
LCP
ID
No
15-49
SW
ID
Control
Card
15-50
SW
ID
Power
Card
15-51
Frequency
Converter
Serial
Number
15-53
Power
Card
Serial
Number
15-59
CSIV
Filename
15-6*
Option
Ident
15-60
Option
Mounted
15-61
Option
SW
Version
15-62
Option
Ordering
No
15-63
Option
Serial
No
15-70
Option
in
Slot
A
15-71
Slot
A
Option
SW
Version
15-72
Option
in
Slot
B
15-73
Slot
B
Option
SW
Version
15-74
Option
in
Slot
C0
15-75
Slot
C0
Option
SW
Version
15-76
Option
in
Slot
C1
15-77
Slot
C1
Option
SW
Version
15-9*
Parameter
Info
15-92
Defined
Parameters
15-93
Modified
Parameters
15-98
Drive
Identification
15-99
Parameter
Metadata
16-**
Data
Readouts
16-0*
General
Status
16-00
Control
Word
16-01
Reference
[Unit]
16-02
Reference
%
16-03
Status
Word
16-05
Main
Actual
Value
[%]
16-09
Custom
Readout
16-1*
Motor
Status
16-10
Power
[kW]
16-11
Power
[hp]
16-12
Motor
Voltage
16-13
Frequency
16-14
Motor
Current
16-15
Frequency
[%]
16-16
Torque
[Nm]
16-17
Speed
[RPM]
16-18
Motor
Thermal
16-19
KTY
sensor
temperature
16-20
Motor
Angle
16-21
Torque
[%]
High
Res.
16-22
Torque
[%]
16-25
Torque
[Nm]
High
16-3*
Drive
Status
16-30
DC
Link
Voltage
16-32
Brake
Energy
/s
16-33
Brake
Energy
/2
min
16-34
Heatsink
Temp.
16-35
Inverter
Thermal
16-36
Inv.
Nom.
Current
16-37
Inv.
Max.
Current
16-38
SL
Controller
State
16-39
Control
Card
Temp.
16-40
Logging
Buffer
Full
16-41
LCP
Bottom
Statusline
16-49
Current
Fault
Source
16-5*
Ref.
&
Feedb.
16-50
External
Reference
16-51
Pulse
Reference
16-52
Feedback
[Unit]
16-53
Digi
Pot
Reference
16-57
Feedback
[RPM]
16-6*
Inputs
&
Outputs
16-60
Digital
Input
16-61
Terminal
53
Switch
Setting
16-62
Analog
Input
53
16-63
Terminal
54
Switch
Setting
16-64
Analog
Input
54
16-65
Analog
Output
42
[mA]
16-66
Digital
Output
[bin]
16-67
Freq.
Input
#29
[Hz]
16-68
Freq.
Input
#33
[Hz]
16-69
Pulse
Output
#27
[Hz]
16-70
Pulse
Output
#29
[Hz]
16-71
Relay
Output
[bin]
16-72
Counter
A
16-73
Counter
B
16-74
Prec.
Stop
Counter
16-75
Analog
In
X30/11
16-76
Analog
In
X30/12
16-77
Analog
Out
X30/8
[mA]
16-78
Analog
Out
X45/1
[mA]
16-79
Analog
Out
X45/3
[mA]
16-8*
Fieldbus
&
FC
Port
16-80
Fieldbus
CTW
1
16-82
Fieldbus
REF
1
16-84
Comm.
Option
STW
16-85
FC
Port
CTW
1
16-86
FC
Port
REF
1
16-9*
Diagnosis
Readouts
16-90
Alarm
Word
16-91
Alarm
Word
2
16-92
Warning
Word
16-93
Warning
Word
2
16-94
Ext.
Status
Word
17-**
Feedback
Option
17-1*
Inc.
Enc.
Interface
17-10
Signal
Type
17-11
Resolution
(PPR)
17-2*
Abs.
Enc.
Interface
17-20
Protocol
Selection
17-21
Resolution
(Positions/Rev)
17-24
SSI
Data
Length
17-25
Clock
Rate
17-26
SSI
Data
Format
17-34
HIPERFACE
Baud
rate
17-5*
Resolver
Interface
17-50
Poles
17-51
Input
Voltage
17-52
Input
Frequency
17-53
Transformation
Ratio
17-56
Encoder
Sim.
Resolution
17-59
Resolver
Interface
17-6*
Monitoring
and
App.
17-60
Feedback
Direction
17-61
Feedback
Signal
Monitoring
18-**
Data
Readouts
2
18-3*
Analog
Readouts
18-36
Analog
Input
X48/2
[mA]
18-37
Temp.
Input
X48/4
18-38
Temp.
Input
X48/7
18-39
Temp.
Input
X48/10
18-6*
Inputs
&
Outputs
2
18-60
Digital
Input
2
18-90
PID
Readouts
18-90
Process
PID
Error
18-91
Process
PID
Output
18-92
Process
PID
Clamped
Output
18-93
Process
PID
Gain
Scaled
Output
30-**
Special
Features
30-0*
Wobbler
30-00
Wobble
Mode
30-01
Wobble
Delta
Frequency
[Hz]
30-02
Wobble
Delta
Frequency
[%]
30-03
Wobble
Delta
Freq.
Scaling
Resource
30-04
Wobble
Jump
Frequency
[Hz]
30-05
Wobble
Jump
Frequency
[%]
30-06
Wobble
Jump
Time
30-07
Wobble
Sequence
Time
30-08
Wobble
Up/Down
Time
30-09
Wobble
Random
Function
30-10
Wobble
Ratio
30-11
Wobble
Random
Ratio
Max.
30-12
Wobble
Random
Ratio
Min.
30-19
Wobble
Delta
Freq.
Scaled
30-2*
Adv.
Start
Adjust
30-20
High
Starting
Torque
Time
[s]
30-21
High
Starting
Torque
Current
[%]
30-22
Locked
Rotor
Protection
30-23
Locked
Rotor
Detection
Time
[s]
30-8*
Compatibility
(I)
30-80
d-axis
Inductance
(Ld)
30-81
Brake
Resistor
(ohm)
30-83
Speed
PID
Proportional
Gain
30-84
Process
PID
Proportional
Gain
31-**
Bypass
Option
31-00
Bypass
Mode
31-01
Bypass
Start
Time
Delay
31-02
Bypass
Trip
Time
Delay
31-03
Test
Mode
Activation
31-10
Bypass
Status
Word
31-11
Bypass
Running
Hours
31-19
Remote
Bypass
Activation
32-**
MCO
Basic
Settings
32-0*
Encoder
2
32-00
Incremental
Signal
Type
32-01
Incremental
Resolution
32-02
Absolute
Protocol
32-03
Absolute
Resolution
32-04
Absolute
Encoder
Baud
Rate
X55
32-05
Absolute
Encoder
Data
Length
32-06
Absolute
Encoder
Clock
Frequency
32-07
Absolute
Encoder
Clock
Generation
32-08
Absolute
Encoder
Cable
Length
32-09
Encoder
Monitoring
32-10
Rotational
Direction
32-11
User
Unit
Denominator
32-12
User
Unit
Numerator
32-13
Enc.2
Control
32-14
Enc.2
node
ID
32-15
Enc.2
CAN
guard
32-3*
Encoder
1
32-30
Incremental
Signal
Type
32-31
Incremental
Resolution
32-32
Absolute
Protocol
32-33
Absolute
Resolution
32-35
Absolute
Encoder
Data
Length
About Adjustable Frequency ...
VLT
®
AutomationDrive Instruction
Manual
MG.33.AI.22 - VLT
®
is a registered Danfoss trademark
5-7
5
5