0-12 This Set-up Linked to
Option:
Function:
automatically in Set-up 1. A switch between
Set-up 1 and Set-up 2 during operation is now
possible.
[0]
*
Not linked
[1]
Set-up 1
[2]
Set-up 2
[3]
Set-up 3
[4]
Set-up 4
0-13 Readout: Linked Set-ups
Array [5]
Range:
Function:
0
*
[0 - 255 ] View a list of all the set-ups linked by means of
0-12 This Set-up Linked to
. The parameter has one
index for each parameter set-up. The parameter
value displayed for each index represents which
set-ups are linked to that parameter set-up.
Index
LCP value
0
{0}
1
{1,2}
2
{1,2}
3
{3}
4
{4}
Table 6.3 Example: Set-up 1 and Set-up 2 are
linked
0-14 Readout: Edit Set-ups / Channel
Range:
Function:
0
*
[-2147483648 -
2147483647 ]
View the setting of
for each
of the four different communication
channels. When the number is displayed in
hex, as it is in the LCP, each number
represents one channel.
Numbers 1-4 represent a set-up number; ‘F’
means factory setting; and ‘A’ means active
set-up. The channels are, from right to left:
LCP , FC-bus, USB, HPFB1-5.
Example: The number AAAAAA21h means
that the FC bus selected Set-up 2 in
, the LCP selected Set-up 1
and all others used the active set-up.
6.3.4 0-2* LCP Display
Define the variables displayed in the Graphical Local
Control Panel.
NOTE!
Please refer to
0-37 Display Text 1
,
0-38 Display Text 2
and
0-39 Display Text 3
for information on how to write display
texts.
0-20 Display Line 1.1 Small
Option:
Function:
Select a variable for display in
line 1, left position.
[0]
None
No display value selected.
[1501]
Running Hours
[1600]
Control Word
Present control word
[1603]
Status Word
Present status word.
[1630]
DC Link Voltage
Intermediate circuit voltage in
the unit.
[1634]
Heatsink Temp.
Present heatsink temperature
of the unit. The cut-out limit
is 203°F ±9°F [95°C ± 5°C];
cutting back in occurs at
158°F ±9°F [70°C ± 5°C].
[1635]
Inverter Thermal
Percentage load of the
inverters.
[1636]
Inv. Nom. Current
Nominal current of the unit.
[1637]
Inv. Max. Current
Maximum current of the unit.
[1639]
Control Card Temp.
Temperature of the control
card.
[1660]
Digital Input
Signal states form the 6
digital terminals (18, 19, 27,
29, 32 and 33). There are 16
bits in total, but only six of
them are used. Input 18
corresponds to the leftmost
area of the used bits. Signal
low = 0; Signal high = 1.
[1666]
Digital Output [bin]
Binary value of all digital
outputs.
[1671]
Relay Output [bin]
[1680]
Serial communication
bus CTW 1
Control word (CTW) received
from the bus master.
[1684]
Comm. Option STW
Extended Serial
communication bus communi-
cation option status word.
[1685]
FC Port CTW 1
Control word (CTW) received
from the bus master.
[1690]
Alarm Word
One or more alarms in a Hex
code.
[1691]
Alarm Word 2
One or more alarms in a Hex
code.
How to Program
VLT Active Filter AAF 00x
MG.90.V2.22 - VLT
®
is a registered Danfoss trademark
6-7
6
6