Illustration 4.8: synchronising to a running master
4.6.3. Position Displacement with a Running Master
If one of the Inputs 32 or 33 is activated during synchronous travel, the actual position in relation
to the master is displaced by the value set in Parameter 1910. If the displacement is positive, the
slave accelerates in order to travel the necessary distance in order then again to travel synchro-
nously to the master at the speed determined via the gear ratio. If the displacement is negative,
the slave decelerates in order to attain the necessary distance to then again travel synchronously
with the master at the speed determined via the gear ratio.
Illustration 4.9: Position displacement