3. Programming
3.1. Description of Parameters
19-00 Store data
Option:
Function:
Here you can save the gear-ratio data permanently in the EE-
PROM
[0]
no function
[1]
Gear data is being
saved
While saving, the value remains “1“; when saving is finished,
the value automatically reverts to “0“. At the same time, during
saving, Output O5 “Saving“ is set to “1“. Saving is not possible
during operation, but only in the stopped state.
19-01 Test run; Program 1
Option:
Function:
Test run speed:
Specify here the speed at which the test runs
are to be carried out. The speed is specified as a percentage of
the maximum speed defined in par. 32-80.
19-01 Synchronous operation; Program 2
Option:
Function:
Type of operation: Select here the type of operation of the syn-
chronising Controller
[0]
Speed synchronising
[1]
Position synchronising
[2]
Marker synchronising
[3]
Speed synchronising with motor coast after stop
[4]
Position synchronising with motor coast after stop
[5]
Marker synchronising with motor coast after stop
[6]
.
Speed synchronising with motor coast after stop and setting of
gear ratio via analogue input 54
[7]
Speed synchronising with setting of gear ratio via analogue in-
put 54.
With the selections “0” - “2” and “7” the motor is always controlled keeping the actual position
when stopping synchronisation (input 1 = “0”).
Syncronising Controller MCO 350 Operating
Instructions
3. Programming
MG.33.Q1.02 - VLT
®
is a registered Danfoss trademark
27
3