An old array may exist if the CNF file with all
parameters and arrays has not been loaded
into the
CAM-Editor.
An incorrect array could be caused by the fol-
lowing:
-
It was not created by the curve edi-
tor
-
Previous version of a curve editor.
Such an array must first be conver-
ted by the current CAM-Editor (
→
load
and
save
)
-
Or the order of the arrays in the DIM
instruction does not match the order
in the cnf file. Refer to the number of
the array in the title bar of the
CAM-
Editor
in this respect.
Error 192
Encoder error
Error from encoder monitoring: open or short
circuit in accordance with the displayed LED.
NB!
An error will be indicated even if
no encoder is connected.
Error 199
Internal MCO fault
If such an error should occur, please contact
your dealer and report the error number dis-
played to the technical service department.
Syncronising Controller MCO 350 Operating
Instructions
5. Appendix
MG.33.Q1.02 - VLT
®
is a registered Danfoss trademark
85