32-33 Absolute Resolution (Master)
Option:
Function:
Enter the positions per revolution.
32-35 Absolute Encoder Data Length (Master)
Option:
Function:
Enter the number of data bits of the connected absolute encod-
er.
32-36 Absolute Encoder Clock Frequency (Master)
Option:
Function:
Enter the clock frequency according to the encoder manufac-
turer specifications.
32-37 Absolute Encoder Clock Generation (Master)
Option:
Function:
Off
Clock signal is not generated.
On
Clock signal is generated, this is most commonly used.
32-38 Absolute Encoder Cable Length (Master)
Option:
Function:
Enter the cable length of the encoder, please note that 300 me-
ters is the maximum.
32-39 Encoder Monitoring (Master)
Option:
Function:
Off
No monitoring of encoder hardware.
On
Monitoring of encoder harware, open- or short-curcuit will gen-
erate O.ERR_192.
32-40 Encoder Termination (Master)
Option:
Function:
If only one encoder is connected then select “ON”, for all other
configurations select “OFF”
32-60 P-portion of the synchronising controller
Option:
Function:
Setting: see Examples.
32-61 D-portion of the synchronising controller
Option:
Function:
Setting: see Examples.