VLT 5000 series
FC 302 series
Parameter
405 Reset
14-20 Reset Mode
Options
[0] Manual reset
[0] Off
[1] Automatic reset
x 1
[1] Automatic reset x
1
[2] Automatic reset
x 2
[2] Automatic reset x
2
[3] Automatic reset
x 3
[3] Automatic reset x
3
[4] Automatic reset
x 4
[4] Automatic reset x
4
[5] Automatic reset
x 5
[5] Automatic reset x
5
[6] Automatic reset
x 6
[6] Automatic reset x
6
[7] Automatic reset
x 7
[7] Automatic reset x
7
[8] Automatic reset
x 8
[8] Automatic reset x
8
[9] Automatic reset
x 9
[9] Automatic reset x
9
[10] Automatic reset
x 10
[10] Automatic reset x
10
Table 5.133 Conversion of Parameter 405
VLT 5000 series
FC 302 series
Parameter 406 Automatic restart
time
14-21 Automatic Restart
Time
Range
0 – 10 s
0 – 600 s
Table 5.134 Conversion of Parameter 406
5000 series
FC 302 series
Parameter 407 Mains failure
14-10 Mains Failure
Data range [0] No function
[0] No function
[1] Controlled ramp
down
[1] Controlled ramp down
[2] Controlled ramp
down and trip
[2] Controlled ramp down
and trip
[3] Coast
[3] Coast
[4] Kinetic back-up
[4] Kinetic back-up
[5] Controlled alarm
suppression
[5] Kinetic back-up, trip
Table 5.135 Conversion of Parameter 407
VLT 5000 series
FC 302 series
Parameter
408 Quick discharge
Not converted
Table 5.136 Conversion of Parameter 408
VLT 5000 series
FC 302 series
Parameter 409 Trip delay torque 14-25 Trip Delay at Torque
Limit
Range
0 – 60 s (60=OFF)
0 – 60 s (60=OFF)
Table 5.137 Conversion of Parameter 409
VLT 5000 series
FC 302 series
Parameter 410 Trip delay inverter 14-26 Trip Delay at Inverter
Fault
Range
0 – 35 s
0 – 35 s
Table 5.138 Conversion of Parameter 410
VLT 5000 series
FC 302 series
Parameter 411 Switching frequency 14-01 Switching Frequency
Range
Unsigned 16 (6)
Unsigned 8 (5)
1.5 – 14 kHz
< 2.3
⇒
2.0 kHz [2]
2.3 > 2.7
⇒
2.5 kHz [3]
2.8 > 3.2
⇒
3.0 kHz [4]
3.3 > 3.7
⇒
3.5 kHz [5]
3.8 > 4.5
⇒
4.0 kHz [6]
4.6 > 5.5
⇒
5.0 kHz [7]
5.6 > 6.5
⇒
6.0 kHz [8]
6.6 > 7.5
⇒
7.0 kHz [9]
7.6 > 9.0
⇒
8.0 kHz [10]
9.1 >
⇒
10.0 kHz [11]
Table 5.139 Conversion of Parameter 411
VLT 5000 series
FC 302 series
Parameter 412 Output frequency dependent
switching frequency
Not converted
Table 5.140 Conversion of Parameter 412
VLT 5000 series
FC 302 series
Parameter 413 Overmodulation
function
14-03 Overmodulation
function
Options
[0] Off
[0] Off
[1] On
[1] On
Table 5.141 Conversion of Parameter 413
VLT 5000 series
FC 302 series
Parameter
414 Minimum feedback
Not converted
Table 5.142 Conversion of Parameter 414
VLT 5000 series
FC 302 series
Parameter
415 Maximum feedback
Not converted
Table 5.143 Conversion of Parameter 415
Parameter Mapping Lists
Operating Instructions
MG37E102