Parameter 318 Function after time
out
6-01 Live Zero Timeout
Function
Options
[0] Off
[0] Off
[1] Freeze output
frequency
[1] Freeze output
frequency
[2] Stop
[2] Stop
[3] Jogging
[3] Jog
[4] Max Speed, p202
[4] Max Speed
[5] Stop and trip
[5] Stop and trip
Table 5.105 Conversion of Parameter 318
VLT 5000 series
FC 302 series
Parameter 319 Terminal 42,
Output
Digital = Par. 5-32 DO X30/7
(MCB 101)
Analogue values = Par. 6-50 AO
42
Pulse = Par. 5-66 DO X30/6
Parameter 321 Terminal 45,
Output
Digital = Par. 5-33 DO X30/7
(MCB 101)
Analogue values= Par. 6-60 AO
X30/8
Pulse = Par. 5-66 DO X30/6
Options
[0] No function
Par. 5-32 = [0] No operation
[1] Control Ready
Par. 5-32 = [1] Control Ready
[2] Ready signal
Par. 5-32 = [2] Drive ready
[3] Ready - Remote
Control
Par. 5-32 = [3] Drive rdy/rem ctrl
[4] Enabled, no
warning
Par. 5-32 = [4] Enable / no
warning
[5] Running
Par. 5-32 = [5] VLT
®
running
[6] Running, no
Warning
Par. 5-32 = [6] Running /no
warning
[7] Running within
range, no Warning
Par. 5-32 = [7] Run in range/no
warning
[8] Run at
reference, no
Warning
Par. 5-32 = [8] Run on ref/no
warning
[9] Alarm
Par. 5-32 = [9] Alarm
[10] Alarm or
Warning
Par. 5-32 = [10] Alarm or
Warning
[11] Torque limit
Par. 5-32 = [11] At torque limit
[12] Out of current
range
Par. 5-32 = [12] Out of current
range
[13] Above I low
Par. 5-32 = [13] Below current,
low
1)
[14] Under I high
Par. 5-32 = [14] Above current,
high
1)
Table 5.106 Conversion of Parameters 319 to 321
VLT 5000 series
FC 302 series
Parameter 319 Terminal 42,
Output
Digital = Par. 5-32 DO X30/7
(MCB 101)
Analogue values= Par. 6-50 AO
42
Pulse = Par. 5-66 DO X30/6
Parameter 321 Terminal 45,
Output
Digital = Par. 5-33 DO X30/7
(MCB 101)
Analogue values= Par. 6-60 AO
X30/8
Pulse = Par. 5-66 DO X30/6
Options
[15] Out of
frequency range
Par. 5-32 = [15] Out of speed
range
[16] Over f low
Par. 5-32 = [16] Below speed
low
1)
[17] Under f high
Par. 5-32 = [17] Above speed
high
1)
[18] Out of feedback
range
Par. 5-32 = [18] Out of feedb.
Range
[19] Over feedback
low
Par. 5-32 = [19] Below
feedback low
1)
[20] Under feedback
high
Par. 5-32 = [20] Above
feedback high
1)
[21] Thermal
warning
Par. 5-32 = [21] Thermal
warning
[22] Ready, no
thermal warning
Par. 5-32 = [12] Ready,no
thermal W
[23] Ready - remote
control - no thermal
warning
Par. 5-32 = [23] Remote, ready,
no TW
[24] Ready – mains
voltage within range
Par. 5-32 = [24] Ready, Voltage
OK
[25] Reversing
Par. 5-32 = [25] Reverse
[26] Bus OK
Par. 5-32 = [26] Bus OK
[27] Torque limit
and stop
Par. 5-32 = [27] Torque limit &
stop
Table 5.107 Conversion of Parameters 319 to 321