1
L1 connection
2
L2 connection
3
L3 connection
4
+LV connection plugged (con gurable, see +CG option below)
5
Cooling inlet / outlet connections
6
X2 temperature measurement connector
7
+LV connection cable gland (con gurable, see +CG option below)
8
X1 plugged, not in use
9
M8 Mounting points, 6 pcs on the sides and 8 pcs on the bottom
+CG1 option comes with a selection of cable glands and plugs. Typical cable gland con gurations
are shown in the Table below.
Table 3. Typical cable gland con gurations for CG1
Connections
Typical cable gland applications
Connection to DC/DC-converter (L1, L2,
L3)
3x M25 cable glands
3x M25 cable glands
3x M25 cable glands
Low voltage side positive connection
(+LV)
1x M32 cable gland, 2x M32
plugs
2x M32 cable glands, 1x M32
plugs
3x M32 cable glands, no
plugs
Intended use of the electric device
The electric device is intended only for professional use. Installation, operation and maintenance of the electric
device is permitted only for trained personnel and professionals.
The electric device is intended for xed installation, as a part of complete power generation equipment or system.
Typical applications for the electric device are:
System component designed to be combined with EC-C1200-450 DCDC-converter, used to
transfer energy between two different voltage levels.
Figure 2. Application example
EC-LTS1200-410
3. Product overview
| BC355449988603en-000101
©