Piranha HS-xx RoHS User Manual
Teledyne DALSA
03-032-20013-03
93
Mnemonic
Syntax Parameters Description
set d igital offset
sdo
t i
Su btracts the inp u t valu e from the
vid eo signal p rior to FPN correction.
t
= Tap valu e.
0
for all tap s or
1
-
number of CCD taps
for ind ivid u al
tap selection.
i
= Offset in a range from
0
to
511
DN .
Refer to
Setting Digital Offset on p age62 for
d etails.
set exp osu re m od e
sem
m
Set the exp osu re m od e:
3 =
External SYN C, m axim u m
exp osu re tim e
7 =
Internal p rogram m able SYN C,
m axim u m exp osu re tim e. Factory
setting.
set fp n coeff
sfc
x i
Set the FPN coefficient.
x
=p ixel nu m ber w ithin the range
1
to
sensor pixel count
.
i
= FPN valu e w ithin the range
0
to
2048
(12-bit LSB).
Refer to Perform ing FPN Correction on
p age 62 for d etails.
set fp n range
sfr
x1 x2 i
Set a range of p ixel FPN coefficients
x1
=first p ixel nu m ber of the range.
x2
=last p ixel nu m ber of the range
i
=coefficient valu e in a range from
0
to
2048
.
Refer to Setting a Range of FPN
Coefficients on p age 62 for d etails.
set low er threshold
slt
i
The p ixels below the low er threshold
are checked for and rep orted in the
end -of-line sequ ence in a range from
0
-
4095
. Refer to section 4.5.3 End -of-line
Sequ ence for d etails.
set m irror m od e
smm
i
Set the camera’s mirror mode:
0
: Pixels read ou t left to right (1 to 4096
or 8192)
1
: Pixels read ou t right to left (8092 or
4096 to 1)
Refer to 4.4.4 Setting the Pixel Read ou t
Direction for d etails.