Piranha HS-xx RoHS User Manual
Teledyne DALSA
03-032-20013-03
95
Mnemonic
Syntax Parameters Description
set sync frequ ency
ssf
i
Set the fram e rate to a valu e from :
TDI
H S-40-4k40:
3499.87
-
36563.1
H S-80-8k40:
3499.56
-
34305.3
H S-80-8k80:
3499.87
-
68610.6
H S-82-4k80:
3499.87-111111
Area
H S-40-4k40:
1
-
3783.58
H S-80-8k40:
1
-
3084.52
H S-80-8k80:
1
-
6169.03
H S-82-4k80:
1-9017.13
Valu e rou nd ed u p / d ow n as requ ired .
Refer to
Setting Fram e Rate on p age 42 for
d etails.
set system gain
ssg
t i
Set the d igital gain.
t
= tap selection , either
1
to
number
of CCD taps
, or
0
for all tap s
i
= Digital gain in a range from
0
to
65535
. The d igital vid eo valu es are
m u ltip lied by this nu m ber. Refer to
Setting Digital Gain on p age 61 for
d etails.
stage select
stg
i
Sets the nu m ber of TDI stages.
Allow able valu es (not inclu d ing the H S-
82 m od el) are:
16,32
,
48
,
64
,
80
,
96
(d efau lt)
Allow able H S-82 valu es are:
8,16,24,32
,
40
,
48
(d efau lt)
Refer to 4.2 Selecting the N u m ber of
CCD Integration Stages for d etails.
set u p p er threshold
sut
i
The p ixels equ al to or greater than the
u p p er threshold are checked for and
rep orted in the end -of-line sequ ence in
a range from
0
-
4095
. Refer to 4.5.3
End -of-line Sequ ence for d etails.
set vid eo m od e
svm
i
Sw itch betw een norm al vid eo m od e
and test p atterns:
0
: N orm al vid eo m od e
1
: Test p attern
2
: Test p attern
3
: Test p attern
Refer to section 4.7.1 Generating a Test
Pattern for d etails.
set TDI m od e
tdi
i
Set the camera’s operating mode.
0
: Area Mod e
1
: TDI Mod e
Refer to section 4.5.1 for d etails.
All manuals and user guides at all-guides.com