Piranha HS-xx RoHS User Manual
Teledyne DALSA
03-032-20013-03
91
Mnemonic
Syntax Parameters Description
get line average
gla
x1 x2
Read the average of line sam p les.
x1
= Pixel start nu m ber
x2
= Pixel end nu m ber
in a range from
1
to
sensor pixel
count
.
Refer to Retu rning Averaged Lines of
Vid eo on p age 76 for d etails.
get p rnu coeff
gpc
x
Read the PRN U coefficient.
x
= p ixel nu m ber to read in a range
from
1
–
sensor pixel count
.
Refer to Setting a range of Pixel PRN U
Coefficients for d etails.
get signal frequ ency
gsf
i
Read s the requ ested Cam era Link
control frequ ency.
1
= EXSYN C frequ ency
2
= Sp are
3
= Direction (1 = forw ard , 2 = reverse)
4
= Sp are
help
h
Disp lay the online help . Refer to section
for d etails.
load p ixel coefficients
lpc
Load s the p reviou sly saved p ixel
coefficients from non -volatile m em ory
w here
i
is:
0
= Factory calibrated coefficients
1
= Coefficient set one
2
= Coefficient set tw o
3
= Coefficient set three
4
= Coefficient set fou r
Refer to section 4.6.2 Saving and
Restoring PRN U and FPN Coefficients
for d etails.
reset cam era
rc
Reset the entire cam era (reboot). Bau d
rate is not reset and reboots w ith the
valu e last u sed .
restore factory settings
rfs
Restore the camera’s factory settings.
FPN and PRN U coefficients reset to 0.
Refer to section 4.6 Saving and
Restoring Settings for d etails.
region of interest
roi
x1 y1 x2
y2
Sets the p ixel range affected by the
ccg
,
cao
,
gl
,
gla
,
ccf
,
cpa
and
ccp
com m and s. The p aram eters are the
p ixel start and end valu es (
x1
and
x2
)
and the colu m n start and end valu es
(
y1
and
y2
) in a range from
1
to
sensor pixel count
. Refer to
section 4.5.1 Setting a Region of Interest
for d etails.
reset p ixel coeffs
rpc
Reset the p ixel coefficients to 0. Refer to
section Enabling and Disabling Pixel
Coefficients on p age 67 for d etails.
All manuals and user guides at all-guides.com
all-guides.com