Piranha HS-xx RoHS User Manual
03-032-20013-03
Teledyne DALSA
32
ssb set subtract background ti 0-16:0-4095
ssf set sync frequency f 3499.87-68610.6 [Hz]
ssg set system gain ti 0-16:0-65535
stg set stage m 16/32/48/64/80/96/
sut set upper threshold i 0-4095
svm set video mode i 0-2
tdi set area or TDI mode i 0-1
ugr update gain reference
vt verify temperature
vv verify voltage
wfc write FPN coefficients i 1-4
wpc write PRNU coefficients i 1-4
wus write user settings
Example Help Screen for HS-80-08k80 Area Mode Operation
cao calibrate analog offset ti 0-16:0-255
ccf correction calibrate fpn NA
ccg calibrate camera gain iti 1-3:0-16:1024-4055
ccp correction calibrate prnu NA
clm camera link mode m 5/16/21/
cpa calculate prnu algorithm ii NA
css correction set sample m NA
dpc display pixel coeffs xx NA
els end of line sequence i 0-1
epc enable pixel coefficients ii NA
gcm get camera model
gcp get camera parameters
gcs get camera serial
gcv get camera version
get get values s
gfc get fpn coeff x NA
gh get help
gl get line xx NA
gla get line average xx NA
gpc get prnu coeff x NA
gsf get signal frequency i 1-4
gss get sensor serial
h help
lpc load pixel coefficients i NA
rc reset camera
rfs restore factory settings
roi region of interest xyxy 1-8192:1-96:1-8192:1-96
rpc reset pixel coeffs
rus restore user settings
sag set analog gain tf 0-16:-10.0-+10.0
sao set analog offset ti 0-16:0-255
sbh set binning horizontal m 1/2/4/8/
sbr set baud rate m 9600/19200/57600/115200/
sbv set binning vertical i 1-8
scd set_ccd_direction i 0-1
sdo set digital offset ti 0-16:0-2048
sem set exposure mode m 3/7/
sfc set fpn coeff xi NA
sfr set fpn range xxi NA
slt set lower threshold i 0-4095
smm set mirroring mode i 0-1
sot set output throughput m 160/320/640/
spc set prnu coeff xi NA
spr set prnu range xxi NA
spt set pretrigger i 0-16
ssb set subtract background ti 0-16:0-4095
All manuals and user guides at all-guides.com