ssf set sync frequency f 1-6169.03 [Hz]
ssg set system gain ti 0-16:0-65535
stg set stage m 16/32/48/64/80/96/
sut set upper threshold i 0-4095
svm set video mode i 0-2
tdi set TDI or area mode i 0-1
ugr update gain reference
vt verify temperature
vv verify voltage
wfc write FPN coefficients i NA
wpc write PRNU coefficients i NA
wus write user settings
4.1 First Power Up Camera Settings
When the cam era is p ow ered u p for the first tim e, it op erates u sing the follow ing factory
settings:
TDI m od e
Left to right p ixel read ou t
Forw ard CCD shift d irection
96 integration stages
N o binning
Cam era Link Mod e
4k: 15 (8 bit, 4 tap s, 40MH z strobe rate)
8k: 21 (8 bit, 8 tap s, 40MH z strobe rate)
Exp osu re m od e 7
10kH z line rate
160 (H S-4k) or 320 (H S-8k) throu ghp u t
Factory calibrated analog gain and offset
Factory calibrated FPN and PRN U coefficients u sing the follow ing p rocess:
ssf
10000
(line rate of 10000H z)
ccg
2 0 3280
(analog gain calibrated to an average p ixel valu e of
3280)
ccf
(fp n calibration)
cpa
2 3920
(calcu late PRN U algorithm )
ssg
0 4096
(set system gain)