Si39-303
Test Operation
General Information
81
a. “
Setting mode 1
”
∗
Setting No. 1, 5, 6 are the present status display only.
Display for malfunction/preparing/test-run
Display during low noise operation
Display during demand operation
No.
Setting (displaying) item
LED display example
H1P
H2P
H3P
H4P
H5P
H6P
H7P
1
Display for malfunction /
preparing / test run
∗
7
7
8
7
7
7
7
2
C/H selector (individual)
7
7
8
7
7
7
7
3
C/H selector (Master)
7
7
7
8
7
7
7
4
C/H selector (Slave)
7
7
7
7
8
7
7
5
Low noise operation
∗
7
7
"
7
7
7
7
6
Demand operation
∗
7
7
"
7
7
7
7
Normal
7
7
8
7
7
7
7
Malfunction
7
8
8
7
7
7
7
Preparing/Test-run
7
9
8
7
7
7
7
Normal
7
7
8
7
7
7
7
During low noise operation
7
7
8
7
7
8
7
H3P to H5P LED
display changes
depending on
setting No. 2, 3, 4.
Normal
7
7
8
7
7
7
7
During demand operation
7
7
8
7
7
7
8
H3P to H5P LED
display changes
depending on
setting No. 2, 3, 4.
8
: ON
7
: OFF
9
: Blinking
<Selection of setting items>
Push the SET button (BS2) and set
LED display to a setting item you
want.
l
Regarding setting item No. 1,5,6,
only the present status is
displayed. For the respective
description, refer to the table
shown on lower right.
l
The cool/heat selection setting can
be changed on setting item 2, 3, 4.
→
After setting, push the RETURN
button (BS3) and decide the
item.
When the RETURN button (BS3) is
pushed, the status becomes the initial
status of “Setting mode 1”.
“Normally, “Setting mode 1” is set.
In case of other status, push MODE
button (BS1) one time and set to
“Setting mode 1”.
(V2763)
Summary of Contents for VRV II Series
Page 6: ...Si39 303 iv Table of Contents...
Page 31: ...Si39 303 Installation General Information 25 Flaring Procedure...
Page 124: ...Appendix Si39 303 118 General Information 3P114237A...
Page 141: ...Si39 303 Appendix General Information 135 RXYQ8MY1B RXYQ10MY1B RXYQ12MY1B 4D040338A...
Page 142: ...Appendix Si39 303 136 General Information RXYQ14MY1B RXYQ16MY1B 4D040339A...
Page 144: ...Appendix Si39 303 138 General Information 7 11 Wiring Diagrams 7 11 1 Outdoor Unit RXYQ5MY1B...
Page 145: ...Si39 303 Appendix General Information 139 RXYQ8MY1B RXYQ10MY1B RXYQ12MY1B 3D038582...
Page 146: ...Appendix Si39 303 140 General Information RXYQ14MY1B RXYQ16MY1B 3D038058...
Page 147: ...Si39 303 Appendix General Information 141 7 11 2 Field Wiring RXYQ5 16MY1B 3D040746...
Page 148: ...Appendix Si39 303 142 General Information RXYQ18 32MY1B 3D040747...
Page 149: ...Si39 303 Appendix General Information 143 RXYQ34 48MY1B 3D040748...
Page 158: ...Appendix Si39 303 152 General Information...
Page 180: ...Refrigerant Piping Si39 303 174 Installation Manual...
Page 226: ...Troubleshooting Si39 303 220 Operation Manual...