SiUS372201EB
Specifications
Part 1 General Information
40
Model name
REYQ120AAYDA
REYQ144AAYDA
Power supply
3 phase, 460 V, 60 Hz
3 phase, 460 V, 60 Hz
1 Cooling
capacity
Nominal
Btu/h
(kW)
120,000 (35.2)
144,000 (42.2)
Rated
114,000 (33.4)
138,000 (40.4)
2 Heating
capacity
Nominal
Btu/h
(kW)
135,000 (39.6)
162,000 (47.5)
Rated
129,000 (37.8)
154,000 (45.1)
Casing color
Ivory white (5Y7.5/1)
Ivory white (5Y7.5/1)
Dimensions: (H × W × D)
in. (mm)
65-3/8 × 48-13/16 × 30-1/8 (1,660 × 1,240 × 765)
65-3/8 × 48-13/16 × 30-1/8 (1,660 × 1,240 × 765)
Heat exchanger
Cross fin coil
Cross fin coil
Compressor Type
Hermetically sealed scroll type
Hermetically sealed scroll type
Volume
m³/h
12.6 + 12.6
11.6 + 18.6
Number of
revolutions
r/min
5,934 + 5,934
5,496 + 5,496
Motor output
kW
3.63 + 3.63
3.36 + 5.72
Starting method
Soft start
Soft start
Fan
Type
Propeller fan
Propeller fan
Motor output ×
Number of units
kW
0.65 × 2
0.65 × 2
Airflow rate
cfm
(m³/min)
8,965 (253.9)
9,675 (274)
Drive
Direct drive
Direct drive
Connecting
pipes
Liquid pipe
in. (mm)
1/2 (12.7) C1220T (brazing connection)
1/2 (12.7) C1220T (brazing connection)
Suction gas pipe
in. (mm)
1-1/8 (28.6) C1220T (brazing connection)
1-1/8 (28.6) C1220T (brazing connection)
High/Low pressure
gas pipe
in. (mm)
3/4 (19.1) C1220T (brazing connection)
7/8 (22.2) C1220T (brazing connection)
Weight
lbs (kg)
728 (330)
800 (363)
Sound pressure level
(Reference data)
dB(A)
61
65
Sound power level
(Reference data)
dB
82
84
Safety devices
High pressure switch, Fan driver overload protector,
Overcurrent fuse, Inverter overload protector,
Leak detecting device
High pressure switch, Fan driver overload protector,
Overcurrent fuse, Inverter overload protector,
Leak detecting device
Defrost method
Deicer
Deicer
Capacity control
%
3-100
3-100
Refrigerant
Refrigerant name
R-410A
R-410A
Charge
lbs (kg)
25.8 (11.7)
25.8 (11.7)
Control
Electronic expansion valve
Electronic expansion valve
Standard accessories
Installation manual, Operation manual,
Connection pipes, Clamps
Installation manual, Operation manual,
Connection pipes, Clamps
Drawing No.
4D134608A
4D134609A
Notes:
1.
2.
Indoor temp.: 80°FDB (26.7°CDB), 67°FWB (19.4°CWB) / Outdoor temp.: 95°FDB (35.0°CDB) / Rated capacity is certified under AHRI standard 1230.
Indoor temp.: 70°FDB (21.1°CDB) / Outdoor temp.: 47°FDB (8.3°CDB), 43°FWB (6.1°CWB) / Rated capacity is certified under AHRI standard 1230.
Summary of Contents for VRV EMERION REYQ-AATJA
Page 1: ...Service Manual Heat Recovery 60 Hz REYQ AATJA B 208 230 V REYQ AAYDA B 460 V SiUS372201EB...
Page 492: ...Wiring Diagrams SiUS372201EB 485 Part 7 Appendix BS6 8Q54TVJ 2D089122B...
Page 493: ...SiUS372201EB Wiring Diagrams Part 7 Appendix 486 BS10 12Q54TVJ 2D089121B...
Page 499: ...SiUS372201EB Wiring Diagrams Part 7 Appendix 492 FXFQ07 09 12 15 18 24 30 36 48TVJU 3D086460B...
Page 501: ...SiUS372201EB Wiring Diagrams Part 7 Appendix 494 FXZQ05 07 09 12 15 18TAVJU 3D110443A...
Page 505: ...SiUS372201EB Wiring Diagrams Part 7 Appendix 498 FXEQ07 09 12 15 18 24PVJU 3D098557A...
Page 506: ...Wiring Diagrams SiUS372201EB 499 Part 7 Appendix FXDQ07 09 12 18 24MVJU C 3D050501C...
Page 513: ...SiUS372201EB Wiring Diagrams Part 7 Appendix 506 FXHQ12 24 36MVJU 3D048116C...
Page 514: ...Wiring Diagrams SiUS372201EB 507 Part 7 Appendix FXAQ07 09 12 18 24PVJU 3D075354F...
Page 521: ...SiUS372201EB Wiring Diagrams Part 7 Appendix 514 VAM1200GVJU 3D073270D...