By combining DIN2 ~ DIN5, the pressure and flow rate command value can be selected, as shown in the following
table.
■
Select the PQ selection number by digital input signal
Digital input signal
DIN2 DIN3
DIN4
DIN5
PQ selection
number
The parameters
of the selected
pressure and
flow command
Bit0 Bit1 Bit2 Bit3
0
P13
OFF OFF OFF OFF
1
P14
ON OFF OFF OFF
2
P15
OFF ON OFF OFF
3 P16
ON
ON
OFF
OFF
4 P17
OFF
OFF
ON
OFF
5
P18
ON OFF ON OFF
6 P19
OFF
ON
ON
OFF
7
P20
ON ON ON OFF
8
P21
OFF OFF OFF ON
9 P22
ON
OFF
OFF
ON
10
P23
OFF ON OFF ON
11 P24
ON
ON
OFF
ON
12 P25
OFF
OFF
ON
ON
13 P26
ON
OFF
ON
ON
14
P27
OFF ON ON ON
15
P28
ON ON ON ON
PQ2: Pressure
Setting Value
Pressure
Time
◆Example of the PQ selection switching (Three-stage pressure)
ON
Digital Input 2
(PQ Selection 1)
OFF
OFF
OFF
OFF
OFF
ON
0
ON
ON
ON
PQ5: Pressure
Setting Value
PQ14: Pressure
Setting Value
Digital Input 3
(PQ Selection 2)
Digital Input 4
(PQ Selection 3)
Digital Input 5
(PQ Selection 4)
Summary of Contents for SUT00D4016-30
Page 2: ......
Page 12: ......
Page 20: ...PIM00413 3 6 3 4 Dimensions Motor Pump Type SUT00 SUT00S3016 30 ...
Page 21: ...PIM00413 3 7 SUT00S6007 30 ...
Page 22: ...PIM00413 3 8 SUT00D4016 30 SUT00D6021 30 Product type Dimension ...
Page 23: ...PIM00413 3 9 Unit Type SUT06 SUT10 SUT06S3016 30 ...
Page 24: ...PIM00413 3 10 SUT06S6007 30 ...
Page 25: ...PIM00413 3 11 SUT06D4016 30 SUT06D6021 30 1 1 327 for SUT06D6021 30 2 188 for SUT06D6021 30 2 ...
Page 26: ...PIM00413 3 12 SUT10D6021 30 ...
Page 36: ......
Page 38: ......
Page 42: ......
Page 54: ......
Page 64: ......