PIM00413
13-2
Alarm
Code
Name Reason
Countermeasure
Failure of the encoder
・
Replace the motor pump
Failure of the controller
・
Replace the controller
Failure of the encoder
・
Replace the motor pump
Failure of the controller
・
Replace the controller
E12
Overspeed
Motor rotation speed exceeded
120% of the maximum rotational
speed
Noise
・
Add a noise filter
Short circuit of the regenerative
resistor
・
Replace the regenerative resistor
Resistance value of the
regenerative resistor is too
small.
・
Check the resistance value of the
regenerative
E13
Regenerative brake overcurrent
Regenerative current exceeded the
specified value.
Motor regenerative energy is too
large.
・
Increase the
acceleration/deceleration time
・
Lighten the load
Power supply voltage is out of
the specification range
・
Check the power supply voltage
in monitor mode [n12: main
circuit voltage], and make it in
the required range
E14
Regenerative brake overload
Overload protection of regenerative
resistor is activated.
During deceleration the braking
force is too large
・
Reduce the parameter value of "
P13 ~ P28: deceleration time
setting"
・
Reduce the value of "P05: Load
command rate at the time of
regeneration", "P06: Regenerative
load ratio command at the time of
deceleration"
The power supply voltage is low
・
Check the power supply voltage
in monitor mode [n12: main
circuit voltage], and make it in
the required range
Re-turn on the power when the
display is not completely
disappeared
・
Re-power when the display is
completely disappeared
E15
Undervoltage
Main circuit voltage becomes less
than DC190V
Failure of the controller
・
Replace the controller
Power supply voltage is high
・
Check the power supply voltage
in monitor mode [n12: main
circuit voltage], and make it in
the required range
Failure of the controller
・
Replace the controller
E16
Overvoltage
Main circuit voltage becomes more
than DC400V
Rapid deceleration in PQ
selection switching
・
Reduce the parameter value of "
P13 ~ P28: deceleration time
setting"
・
Reduce the value of "P05: Load
command rate at the time of
regeneration", "P06: Regenerative
load ratio command at the time of
deceleration"
Load torque is large
・
Replace the motor pump
Defects in motor control due to
the effect of noise
・
Replace the controller
E17
Motor electronic thermal error
Overload protection is activated by
electronic thermal
Defects in motor control due to
the effect of noise
・
Add a noise filter
Summary of Contents for SUT00D4016-30
Page 2: ......
Page 12: ......
Page 20: ...PIM00413 3 6 3 4 Dimensions Motor Pump Type SUT00 SUT00S3016 30 ...
Page 21: ...PIM00413 3 7 SUT00S6007 30 ...
Page 22: ...PIM00413 3 8 SUT00D4016 30 SUT00D6021 30 Product type Dimension ...
Page 23: ...PIM00413 3 9 Unit Type SUT06 SUT10 SUT06S3016 30 ...
Page 24: ...PIM00413 3 10 SUT06S6007 30 ...
Page 25: ...PIM00413 3 11 SUT06D4016 30 SUT06D6021 30 1 1 327 for SUT06D6021 30 2 188 for SUT06D6021 30 2 ...
Page 26: ...PIM00413 3 12 SUT10D6021 30 ...
Page 36: ......
Page 38: ......
Page 42: ......
Page 54: ......
Page 64: ......