PIM00413
13-5
Warning
Code
Name Reason
Countermeasures
Motor cooling fan is stopped
・
Replace the fuse for motor
cooling fan
・
Replace the motor cooling fan
・
Replace the controller
Radiator is clogged
・
Replace or clean the radiator
Rotation speed of the motor is
rising
・
Check the leakage amount in
the main unit side circuit
・
Check the setting of the high-
pressure safety valve
・
Replace the motor pump
L44
Motor temperature
abnormal warning
Motor temperature exceeded
the specified value 83
℃
for
10 seconds or more
The ambient temperature is
high
・
Install it in the place where the
ambient temperature is within
the required range
・
Install in well-ventilated place
The cooling fan for controller
is stopped
・
Replace the fuse for cooling
fan
・
Replace the cooling fan
・
Replace the controller
Radiator is clogged
・
Replace or clean the radiator
L45
Fin temperature abnormal
warning
Fin temperature exceeded the
specified value 73
℃
for 10
seconds or more
Rotation speed of the motor is
rising
・
Check the leakage amount in
the main unit side circuit
・
Check the setting of the high-
pressure safety valve
・
Replace the motor pump
The power supply voltage is
low
・
Check the power supply voltage
in monitor mode [n12: main
circuit voltage], and make it in
the required range
L50
Power supply voltage drop
warning
Main circuit DC voltage is
below the specified
value:DC430V(Power supply
voltage convertion
AC304V)-2 sec.
Failure of the controller
・
Replace the controller
The power supply voltage is
low
・
Check the power supply voltage
in monitor mode [n12: main
circuit voltage], and make it in
the required range
Pump failure
・
Replace the motor pump
L60
Pressure deviation
abnormal warning
Current command is
saturated
Encoder phase is shifted by
noise (no F)
・
Add a noise filter
Setting mistake of pressure
switch setting value
・
Check the pressure switch
setting value
L62
Pressure drop warning
Pressure switch is activated
for 30 seconds or more
consecutive.
Oil leakage from main engine
・
Improve the oil leakage in
main unit side
L63
Pressure switch activation
Pressure switch is activated
Pressure becomes less than the
setting value of the parameter
"P01: Pressure switch"
・
If there is no abnormality in
main machine, please review
the parameter settings for the
pressure switch.
Please refer to
the "12.5 Pressure switch
setting" for more information.
Summary of Contents for SUT00D4016-30
Page 2: ......
Page 12: ......
Page 20: ...PIM00413 3 6 3 4 Dimensions Motor Pump Type SUT00 SUT00S3016 30 ...
Page 21: ...PIM00413 3 7 SUT00S6007 30 ...
Page 22: ...PIM00413 3 8 SUT00D4016 30 SUT00D6021 30 Product type Dimension ...
Page 23: ...PIM00413 3 9 Unit Type SUT06 SUT10 SUT06S3016 30 ...
Page 24: ...PIM00413 3 10 SUT06S6007 30 ...
Page 25: ...PIM00413 3 11 SUT06D4016 30 SUT06D6021 30 1 1 327 for SUT06D6021 30 2 188 for SUT06D6021 30 2 ...
Page 26: ...PIM00413 3 12 SUT10D6021 30 ...
Page 36: ......
Page 38: ......
Page 42: ......
Page 54: ......
Page 64: ......